The remote control 

The room air conditioner is operated using the infrared 
remote control. 
A beep indicates that a button has been pressed and 
the signal has been correctly received. 

3    Swing button 

When the unit is switched on (ON), the oscillating 
blade improves air distribution of the outlet opening 
in the room. 

 

4    Timer button

 

You can program the unit to automatically switch on 
or off within the next 24 hour-period with the Timer 
button. 

 

5    Sleep button

 

If the Sleep function is activated, the set room tem-
perature increases by 1°C after one hour. This func-
tion can be reset by pressing any button. 

 

6    Mode buttons 1 to 4

 

The room air-conditioner has 4 modes: 
1.   Cooling mode:          
     

COOL button

 

In this mode, the warm air in the room is cooled 
to the desired temperature. When the mechanism 
which prevents the unit from switching back on 
for approx. 3 minutes is active, the COMP. dis-
play blinks. 

2.   Heating mode:         

          

HEAT button 

Heating mode is not active for these units. 

3.   Dehumidification mode:     

          

DRY button 

In this mode, the room is primarily dehumidified 
and the set temperature is maintained. 

4.   Automatic mode:      

AUTO HEAT button 

In this mode, the unit operates like it does in cool-
ing mode. The difference between the point at 
which it switches on and off (hysterisis) is higher 
than in cooling mode. 

 

7    Temp. button 

The temperature button can be used to set the de-
sired temperature in 0.5 °C increments between 15 °C 
and 30 °C. 

1    On / Off button 

Press this button to turn the unit on. 

The POWER display lights up. 

 

2    Fan button 

Set the fan speed you want with this button. 

The following 4 speeds are available: 
Automatic, low, medium and high.

 

Manual operation 

The unit can be put into operation manually, e.g. if the 
remote control is not operating properly or is lost. 

For the RKV 10 W to RKV 18 W units, open the air in-
take grille and press the ON / OFF button on the right 
side of the control panel. 

For the RKV 24 W unit, press the button        on the 
front of the housing. 
The following operating modes are then activated: 

MODE :        Auto mode         TEMP. :         24°C 
FAN:             Automatic          SWING:        On 
TIMER:         Off 

Operation 

 
Two to four seconds after the indoor unit has been con-
nected to the power supply, operation can begin. 

Inserting batteries into the remote control 

Prior to initial operation, the batteries supplied with the 
unit (2 type AAA batteries) must be inserted into the re-
mote control. 

1.  Slide off the cover of the battery slot on the back of 

the remote control and insert the batteries. 

2.   Make sure that the polarity is correct.         
     

Use the labelling in the slot. 

3.   Close the battery slot again. 

Содержание RKW 10 W

Страница 1: ...REMKO powerful like a bear REMKO RKV 10 W 13 W 18 W 24 W Multi purpose room air conditioners Edition GB P05 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...n 14 Condensation Connection 15 External Condensation Pump 15 Prior to Initial Operation 17 Initial Operation 17 Environment and Recycling 18 Customer Service and Guarantee 18 Internal Wiring Diagram...

Страница 4: ...the units exclusively within the permissible operating ranges Pay attention to surrounding temperatures Make sure that the unit is kept at a safe distance from flammable materials Do not install the i...

Страница 5: ...e The difference between the point at which it switches on and off hysterisis is higher than in cooling mode 7 Temp button The temperature button can be used to set the de sired temperature in 0 5 C i...

Страница 6: ...unit to switch on or off at a later time If the room air conditioner is to be switched on at a later time press the or button for approximately 2 seconds when the unit is off In both operating modes...

Страница 7: ...ou hear a beep the COMP display begins to blink for approximately 3 minutes This waiting period is a forced pause to increase the service life of the compressor and the outdoor part Once the display s...

Страница 8: ...the filters and close the grille Maintenance and Service Shutting Down the Unit Temporary shutdown 1 Switch the indoor unit off using the remote control 2 Disconnect the system with the main switch o...

Страница 9: ...nsmission signal at a dis tance of approx 3 m when the but ton is pressed Reduce distance to under 6 m and change location Remote control defective Does the unit work in manual mode Replace remote con...

Страница 10: ...40 65 Power consumption cooling A 0 2 0 2 0 2 0 4 Current consumption max A 0 2 0 2 0 2 0 4 Supply diffuse protection recommended A See corresponding outdoor part Operating range cooling C 15 C bis 30...

Страница 11: ...oid if third party components are used Remember that when installing and maintaining air conditioners high pressure refrigerant lines and electrical current can pose hazards During unit operation some...

Страница 12: ...n and con trol lines see figure below 4 3 2 1 5 Units RKV 10 W RKV 13 W and RKV 18 W can be connected using all five options while the RKV 24 W units can only be connected using options 1 to 3 1 Outfl...

Страница 13: ...5 If you have selected Option 2 or 4 drainage through the wall guide the condensation water and control line through the wall lead through to the indoor unit If you also need a condensation pump it mu...

Страница 14: ...terminal strip of the connection towards you out of the unit Please observe the following We recommend that the customer install a main or repair switch close to the outdoor part Power is supplied to...

Страница 15: ...n If the unit is being operated at outside temperatures below 0 C the lines must be placed in such a way that they are protected from frost External Condensation Pump The condensation pump which can b...

Страница 16: ...ly The end of the ventilation hose must at least be at the same height as the con densation tray to prevent water from overflowing The supplied metal wire clips are used to secure the hose in a vertic...

Страница 17: ...values in the initial operation log Cooling operation test run Perform a test run for cooling operation as follows 1 Switch the customer installed main switch or fuse on 2 Adjust the target temperatur...

Страница 18: ...horised personnel may come into contact with the cold cycle This ensures that refrigerant does not es cape into the environment when the unit is being re paired Both the refrigerant and the system par...

Страница 19: ...tup location Name Street Postal code city Telephone Fax Testing of cycles A B C D Result Visible check Setup of outdoor part and indoor unit R good Q poor Heat exchanger insulation lines R good Q poor...

Страница 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Отзывы: