*     Noise measurement as per  DIN 45635 - 01 - KL3  

Technical Data 

Type 

 

RKV 10 W  RKV 13 W  RKV 18 W 

RKV 24 W 

Cooling capacity 

See corresponding outdoor part 

Area of use room size 

approx. m³ 

90 

120 

160 

230 

Refrigerant 

 R 

407C 

Refrigerant pressure max. / min.

 

kPa 

2800 / 500

 

Connection injection line 

inch (mm) 

3/8 (9.52) 

Connection intake line 

inch (mm) 

1/2 (12.7) 

5/8 (15.9) 

Line length max. 

m 15 

High difference max.  

m 10 

Additional amount to add for 5 m or longer 

g/m 

See corresponding outdoor part 

Electrical connection 

V~ / Hz 

230 / 50. Supplied via control line from outer part 

Power consumption max. 

W 40 40  40 

65 

Power consumption cooling 

A 0.2 0.2  0.2 

0.4 

Current consumption max. 

A 0.2 0.2  0.2 

0.4 

Supply diffuse protection (recommended) 

See corresponding outdoor part 

Operating range cooling 

°C 

+15 °C bis +30 °C 

Dehumidification capacity max. 

l/h 1.1 1.4  1.7 

2.2 

Air performance level     (level 1 / 2 / 3) 

m³/h 

520 / 590 / 700 

615 / 735 / 850  850 / 980 / 1100 

Sound pressure level       (level 1 / 2 / 3)

*

 

dB(A) 

34 / 37 / 45 35 / 38 / 46  36 / 39 / 47 

38 / 42 / 49 

Fans speeds 

 

3 + automatic 

Fan capacity 

W 28 28  28 

50 

Type of protection 

IP X0 

Dimensions: height / width / depth 

mm 

320 / 1000 / 195 

360 / 1213 / 220 

Weight 

kg 13 15  15 

23 

Manufacturer number 

 344... 

354... 422...  354... 

Reference no. 

 

1613508 1613506  1613509 

1613507 

Condensation pump (accessory) 

Ref. No. 

1613167 1613167  1613167 

1613167 

Dimensions 

RKV 10 W / RKV 13 W / RKV 18 W 

RKV 24 W 

1000 

320 

195 

1213 

360 

220 

Содержание RKW 10 W

Страница 1: ...REMKO powerful like a bear REMKO RKV 10 W 13 W 18 W 24 W Multi purpose room air conditioners Edition GB P05 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...n 14 Condensation Connection 15 External Condensation Pump 15 Prior to Initial Operation 17 Initial Operation 17 Environment and Recycling 18 Customer Service and Guarantee 18 Internal Wiring Diagram...

Страница 4: ...the units exclusively within the permissible operating ranges Pay attention to surrounding temperatures Make sure that the unit is kept at a safe distance from flammable materials Do not install the i...

Страница 5: ...e The difference between the point at which it switches on and off hysterisis is higher than in cooling mode 7 Temp button The temperature button can be used to set the de sired temperature in 0 5 C i...

Страница 6: ...unit to switch on or off at a later time If the room air conditioner is to be switched on at a later time press the or button for approximately 2 seconds when the unit is off In both operating modes...

Страница 7: ...ou hear a beep the COMP display begins to blink for approximately 3 minutes This waiting period is a forced pause to increase the service life of the compressor and the outdoor part Once the display s...

Страница 8: ...the filters and close the grille Maintenance and Service Shutting Down the Unit Temporary shutdown 1 Switch the indoor unit off using the remote control 2 Disconnect the system with the main switch o...

Страница 9: ...nsmission signal at a dis tance of approx 3 m when the but ton is pressed Reduce distance to under 6 m and change location Remote control defective Does the unit work in manual mode Replace remote con...

Страница 10: ...40 65 Power consumption cooling A 0 2 0 2 0 2 0 4 Current consumption max A 0 2 0 2 0 2 0 4 Supply diffuse protection recommended A See corresponding outdoor part Operating range cooling C 15 C bis 30...

Страница 11: ...oid if third party components are used Remember that when installing and maintaining air conditioners high pressure refrigerant lines and electrical current can pose hazards During unit operation some...

Страница 12: ...n and con trol lines see figure below 4 3 2 1 5 Units RKV 10 W RKV 13 W and RKV 18 W can be connected using all five options while the RKV 24 W units can only be connected using options 1 to 3 1 Outfl...

Страница 13: ...5 If you have selected Option 2 or 4 drainage through the wall guide the condensation water and control line through the wall lead through to the indoor unit If you also need a condensation pump it mu...

Страница 14: ...terminal strip of the connection towards you out of the unit Please observe the following We recommend that the customer install a main or repair switch close to the outdoor part Power is supplied to...

Страница 15: ...n If the unit is being operated at outside temperatures below 0 C the lines must be placed in such a way that they are protected from frost External Condensation Pump The condensation pump which can b...

Страница 16: ...ly The end of the ventilation hose must at least be at the same height as the con densation tray to prevent water from overflowing The supplied metal wire clips are used to secure the hose in a vertic...

Страница 17: ...values in the initial operation log Cooling operation test run Perform a test run for cooling operation as follows 1 Switch the customer installed main switch or fuse on 2 Adjust the target temperatur...

Страница 18: ...horised personnel may come into contact with the cold cycle This ensures that refrigerant does not es cape into the environment when the unit is being re paired Both the refrigerant and the system par...

Страница 19: ...tup location Name Street Postal code city Telephone Fax Testing of cycles A B C D Result Visible check Setup of outdoor part and indoor unit R good Q poor Heat exchanger insulation lines R good Q poor...

Страница 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Отзывы: