12
REGULUS SRS6 EP Controller - www.regulus.eu
D - TERMINAL CONNECTION
D 1 - Terminal block wiring
Example: solar system with a storage tank and el. heating rod with an integrated thermostat.
Sensor connection - max. 12V
Caution
Mains voltage
100-240V 50Hz
Danger
D 1 - Terminal block wiring
On the circuit board:
SRS6 EP ver. V4:
VFS1
Grundfos Direct Sensor
VFS2 Grundfos
Direct
Sensor
CAN1 CAN
Bus
CAN2 CAN
Bus
S6
VFS2
VFS1
CAN CAN
V1
V2
+
S5
S4
S3
S2
S1
-
PELV
R3I
R3
R2
R1
L
N
N
-
Low voltage - sensor connection
Terminal:
connection for:
S1 Sensor
1
S2 Sensor
2
S3 Sensor
3
S4
Sensor 4
S5 Sensor
5
V1
Output 0-10V / PWM
Terminal „ – „ is connected with a common
terminal block for S1-S4 sensors and VFS
sensors and also with earth on the mains side.
The power supply of low-energy pumps
with 0-10V / PWM pumps can be connected to
the corresponding relay (V1 -> R1, R2 -> V2),
since the relays are switched on and off with
the signal.
Mains voltage 100 - 240V 50Hz
Terminal: connection for:
R2 Relay
2
R1 Relay
1
R3
Relay 3 (normally open, NO)
R3I
Relay 3 (normally closed, NC)
L Mains
phase
N Mains
neutral
PE
protective conductor
(green-yellow)