DISCLAIMER

 

The information in this manual has been carefully checked and is believed to be correct. Regin however, makes no warranties as 

regards the contents of this manual and users are requested to report errors and discrepancies to Regin, so that corrections may 

be made in future editions. The information in this document is subject to change without prior notification.  
The software described in this document is supplied under licence by Regin and may be used or copied only in accordance with 

the terms of the licence.  

COPYRIGHT 

 AB Regin. All rights reserved. 

TRADEMARKS 

Some product names mentioned in this document are used for identification purposes only and may be the registered trademarks 

of their respective companies.  

 

Revision B, May 2019 
Exigo software revision: 4.1 

Содержание EXIGO TOOL

Страница 1: ...MANUAL EXIGO TOOL WE TAKE BUILDING AUTOMATION PERSONALLY Copyright AB Regin Sweden 2019...

Страница 2: ...ons The information in this document is subject to change without prior notification The software described in this document is supplied under licence by Regin and may be used or copied only in accord...

Страница 3: ...status 26 7 6 Inputs Outputs 28 7 7 Time control 28 7 8 Settings 30 7 9 Manual Auto 31 7 10 Configuration 32 CHAPTER 8 EXPANSION UNITS 33 CHAPTER 9 TCP IP NETWORK TERMS 34 9 1 Networks subnets routers...

Страница 4: ...his manual This manual is designed to be an aid during installation and use of Exigo Tool It describes all the functions unique to the program The Exigo control parameters however are not described he...

Страница 5: ...ndows 7 or Windows 8 Windows 8 1 or Windows 10 Communication with an Exigo requires a special communication cable E CABLE2 USB Exigo tool is a self installing program that can be downloaded from Regin...

Страница 6: ...ct access to various functions All functions in the toolbar are also accessible through the menu bar system Below the toolbar there is a row of folder tabs giving access to several folders that can be...

Страница 7: ...ouse button and drag the program name from the folder onto the desktop Release the button and click on Create shortcut here During installation under Windows 8 or Windows 8 1 Exigo Tool is placed unde...

Страница 8: ...manual Exigo Tool always starts with a box where you enter which controller model you are using The Overview folder is also displayed Make sure that you enter the correct model or errors may occur in...

Страница 9: ...ich the relevant model of Exigo is selected If you are unsure of which model you are using the article number can be located on the right hand short side of the controller Make sure that you choose th...

Страница 10: ...ance a temperature the corresponding value in Exigo Tool will not automatically be updated Instead the Exigo Tool user must manually initiate reading of parameter values from the controller Update ini...

Страница 11: ...with the corresponding values in Exigo Tool All discrepancies will be listed All items in the list are normally tick marked By removing the tick mark from an item you can exclude it from the selectio...

Страница 12: ...ate and time with the computer date and time Change controller address This function is used for changing the addresses of the connected controller The address is normally 254 254 If the controller is...

Страница 13: ...ynchronize parameters dialogue window till be displayed Select whether differences in parameter configuration should be updated in Exigo Tool or in the controller After the controller has been reloade...

Страница 14: ...A warning message will now be displayed Click OK The controller has now been repartitioned to make room for the application Next follow the directions above for reloading the controller Another warni...

Страница 15: ...are logged on as Operator or Admin Enables log off to the basic level Change password Only active if you are logged on as Operator or Admin Permits change of the password for the present log on level...

Страница 16: ...Values are recorded every 5 seconds All recorded values can be saved to a textfile for later use in for example a spread sheet program such as Excel Several sessions of the real time chart can be run...

Страница 17: ...the latest recorded values in the parameter list the values at the cursor position are displayed In this way you can check back on earlier record values Go to home Home position is the chart position...

Страница 18: ...xt written here is saved together with the configuration file If you make a printout of the configuration the notepad text is included in the printout Options Permits the setting of some program param...

Страница 19: ...be synchronized Communication Setting of the communication between Exigo tool and controller You can choose if the communication should take place via E CABLE serial or the TCP IP port Serial communic...

Страница 20: ...l ask if you are using a crossover network cable Answer Yes to this question The program will now search for controllers Since no DHCP is available a broadcast address will be used Therefore it is imp...

Страница 21: ...sters the IP adress and the DNS name in the DNS server Each DNS name must be unique The EXOline TCP port 26486 must be open from the controller to the main computer This is especially important when t...

Страница 22: ...Chapter 6 Toolbar The toolbar provides shortcuts to several functions By placing the cursor over a tool icon a tool tip will be displayed giving a short description of the tool All the tools are descr...

Страница 23: ...ox tool tip will be displayed showing the permitted value interval If you have a controller connected you must download a value to the controller for it to become active Downloading can be done in sev...

Страница 24: ...e setting of the parameter Process picture in the System subfolder in the configuration folder Down the left hand edge of the Overview folder there is a list of the most important control parameters T...

Страница 25: ...eated containing the four first recordable parameters in the group 7 4 Consumption Displays consumption values for energy meter heat water meter and cold water meter The values are calculated using pu...

Страница 26: ...rm status in Exigo tool are instantly transmitted to the controller without the need to use Load parameters Changes in alarm status in the controller however are not displayed in Exigo tool until you...

Страница 27: ...will be distributed on 2 rows of 19 characters each If a word in the text extends past the 19th position the whole word will be moved to the second row To avoid this a hyphen can be added in the 19th...

Страница 28: ...d See the box entitled Options under Tools 7 7 Time control Here you set the daily comfort periods Each control function has its own set of daily schedules There are four periods for each day The 8th...

Страница 29: ...choice then click on OK To pick a period click and hold on the first date drag the cursor to the last date and release the button The period will be marked Click OK Alternatively click on the first da...

Страница 30: ...l endpoint values and default value are displayed if you place the cursor over a parameter value Changes must be downloaded to the controller in order to take effect To download right click on a param...

Страница 31: ...outputs A alarm and B alarm respectively if configured Both will activate the Sum alarm output if configured 7 9 Manual Auto In this menu you can take manual command of most controller functions This...

Страница 32: ...ntains all the configuration parameters for the Exigo Since the contents are very diverse the folder has been divided into sub folders These are accessed by clicking on the buttons in the left hand bu...

Страница 33: ...1 and or Initiate Expansion unit 2 will be shown under Tools This initiation function is used for Exigo models which are not factory loaded with version 3 0 For controllers that are factory loaded wit...

Страница 34: ...s Subnet mask Each computer or network connected controller also has a subnet mask consisting of 32 bits Example If the IP address is 192 0 2 73 and the subnet mask is 255 255 255 0 then the subnet ad...

Страница 35: ...IP address 9 4 White and black addresses Black addresses There is a shortage of IP addresses on the Internet and organizations are encouraged to use internal IP addresses on internal networks Differen...

Страница 36: ...onnection via the Internet from a work computer to a main computer on a company network that uses private IP addresses is to create a tunnel going into the network A tunnel means connecting two networ...

Страница 37: ...the fact that it has an integrated web interface Using NAT routing you can also connect more than one web server behind the same white IP address A Exigo can handle a maximum of 5 connections from Ex...

Страница 38: ...30 in the web browser of the client computer you must enter the white IP or DNS of the router followed by 81 in the address field of the web browser Then the web server in the Exigo will send back inf...

Страница 39: ...elect the right cable when asked Then press Search to find the correct Exigo After the program has found the correct Exigo select it and click OK Then click the button TCP IP website and e mail settin...

Страница 40: ...egincontrols com into the address field For more information see the section about CLOUDigo Encrypted communication The encryption is used to prevent other users in the TCP IP network from connecting...

Страница 41: ...onnected directly to the e mail server It cannot be an alias for another network name To test if you have a directly connected network name you can use the Windows command line interpreter to run the...

Страница 42: ...and e mail settings and check the box Activate connection to CLOUDigo Next click on Load TCP IP settings The relevant address for connecting will now be loaded into the controller Once this step has b...