background image

ENGLISH

3

• Fixture must be connected to a 120 Volt, 60 Hz power source. Any other connection

voids warranty.

• This motion activated twin floodlight should be installed by persons with experience in

household wiring or by a qualified electrician. The electrical system, and the method of
electrically connecting the fixture to it, must be in accordance with the National Electrical
Code and local building codes.

• For proper operation and protection against damage, the motion sensor head adjustment

knobs must be facing the ground.

• Disassembly of your fixture will void the warranty.

SAVE THESE  INSTRUCTIONS.

For best results

• Install your fixture 8-12 feet above ground (motion detector is less

sensitive above 12 feet).

• Locate fixture so motion moves across detection zone (M).
• Locate fixture away from heat producing sources to prevent false 

triggering. Also be very careful not to include objects such as 
windows, white walls and water in the detection zone whenever 
possible.

• Locate fixture away from moving objects such as trees and street traffic.
• Do not install more than one motion detector on one wall switch.

Mounting your fixture

Step 1:

Turn off the power at the main fuse/breaker
b ox.

Step 2:

Line up the holes on the mounting bracket with
the holes on your junction box. Using either (2)
#6 screws or (2) #8 screws (depending on size
of the holes in your junction box), attach the
mounting bracket to your junction box (N).

Step 3:

Hang one end of the mounting hook onto the mounting bracket
(using the hole in the bracket, see drawing), and hang the
light fixture on the other end of the mounting hook. NOTE:
Carefully hang the fixture at the base of the lampholder
assembly as shown. This will free-up your hands for
wiring.

Step 4:

Thread fixture wires through coverplate gasket.

Step 5:

If the supply wires coming from your house are
solid,

you can use the Quick-connect™ wire system to attach

your light fixture.

NOTE:

Quick connectors can only be used with

solid wire supply leads. Simply insert the black supply wire
from your house into the quick connector with black wire
coming from the fixture. Repeat for house white wire,
matching to the connector with the white wire. Push
both wires firmly into holes to insure that they are seat-
ed properly and securely (O). It’s that easy!  

Proceed to

Step 7.

Step 6:

If the supply wires coming from your house are strand-
ed,

remove the quick connectors from the end of the light

fixture wires by turning them repeatedly from left to right
while pulling. Repeat until they are both removed.

Remember: Quick connectors can only be used with
solid wire supply leads.

Do not attempt to use with

other electrical fixtures!  These connectors are
designed to withstand the temperature and Voltage requirements of this
Regent product only.

Once the connectors have been removed, 

connect black wire to house black wire and connect white wire to house white
wire using the wire nuts provided.

Step 7:

Attach copper (or green) colored ground wire (coming from the fixture coverplate)
to house ground wire using wire nuts provided.

Step 8:

Remove fixture from hook and discard hook. Attach fixture to the mounting
bracket using the center bolt provided. Insert plastic color matched plug in 
center bolt hole for finished appearance.

Round        Rectangular (horizontal)     Octagonal

Your fixture mounts to the 

following standard junction boxes:

(eave mount)

M

(wall mount)

N

O

Prewired

quick 

connector

Solid

fixture

wire

Solid house

supply wire

Содержание CSV275RB

Страница 1: ...ENGLISH FRAN AIS ESPA OL SV275RB CSV275RB SV275RWB CSV275RWB Instruction Manual Instrucciones Directives...

Страница 2: ...nterference and 2 this device must accept any interference received including interference that may cause undesired operation Under Part 15 of the FCC Rules any changes or modifications to the motion...

Страница 3: ...xture at the base of the lampholder assembly as shown This will free up your hands for wiring Step 4 Thread fixture wires through coverplate gasket Step 5 If the supply wires coming from your house ar...

Страница 4: ...ren and adults from accidentally turning off the power to this Regetn light fixture By inadvertently turning off the power the mode of operation may be changed If the mode of operation needs to be cha...

Страница 5: ...eep the power to the fixture on 1 time 4 Hour NIGHT TIME ON then Motion Activated Lights should turn on automatically at night 100 bright ness for 4 hours then reset to regular auto motion setting for...

Страница 6: ...he AUTO or NIGHT TIME ON setting next dawn AUTO 4 MIN or AUTO 12 MIN or ALL NIGHT TIME ON MODES Turn the power OFF for 5 seconds then back ON 2 times 6 Hour NIGHT TIME ON then Motion Activated Lights...

Страница 7: ...position motion sensor Is the switch on the bottom of the motion sensor in the test mode Move the switch to the AUTO 4 AUTO 12 or Night Time On position Is the motion detector shadowed Reposition moti...

Страница 8: ...ctrical service or any other failure not resulting from defects in materials or workmanship Damage to the product caused by separately purchased non Company brand replacement bulbs and corrosion or di...

Страница 9: ...ora del recept culo D 2 Tornillos No 8 E 2 Tornillos No 6 F 3 Tuercas de cable G Escuadra de montaje H Perno central I Tap n del agujero central del mismo color J La cubierta del interruptor de luz K...

Страница 10: ...y protecci n adecuados contra posibles da os los botones de ajuste de la cabeza del sensor de movimiento se deben ajustar en direcci n al piso Si por alguna raz n se desarma el portal mparas la garant...

Страница 11: ...de temperatura y voltaje de este producto Regent solamente Una vez que se han retirado los conectores conecte el cable negro al cable negro de la casa y conecte el cable blanco al cable blanco de la c...

Страница 12: ...te de alimentaci n el la caja de fusibles interruptor autom tico principal Paso 2 Localice el interruptor de luz dentro de su caso o rea de cochera que controlar su luz activada por movimiento Paso 3...

Страница 13: ...as TIME ON DE NOCHE y luego la detecci n de movimiento activada Las luces deben encen derse autom ticamente en la noche con una intensidad de 100 por 4 horas y luego reposi cionarse a detecci n de mov...

Страница 14: ...IORES SE ENCIENDEN DURANTE LA NOCHE SIN MOTIVO APARENTE Est llegando corriente a la unidad Compruebe que el interruptor autom tico no haya saltado Aseg rese de que el interruptor de la pared est en la...

Страница 15: ...erruptor que se encuentra en la parte inferior del sensor de movimiento en la modalidad de prueba Mueva el interruptor a la posici n AUTO 4 AUTO 12 NIGHT TIME ON Algo est dando sombra sobre el detecto...

Страница 16: ...O INCIDENTALES RESULTANTES DEL USO DEL PRODUCTO O QUE PUEDAN SURGIR DE CUALQUIER VIOLACION DE ESTA GARANTIA TODAS LA GARANTIAS IMPLICITAS SI EXISTE ALGUNA INCLUYENDO GARANTIAS IMPLICITAS DE COMERCIAL...

Страница 17: ...al I Bouchon de trou central coordonn J Le couvre interrupteur K Crochet de montage L Ce qu il faut savoir Pour usage en plein air uniquement Homologu s UL et cUL pour les endroits humides Cet apparei...

Страница 18: ...ment est moins sensible au dessus de 12 pieds 3 7m Placez le dispositif de mani re qu une personne puisse se d placer travers la zone de d tection M Placez le dispositif loin de toute source de chaleu...

Страница 19: ...ique coordonn dans le trou de boulon central pour obtenir un aspect fini Etape 9 Appliquer un joint silicone autour des bords de la plaque de couvercle et dans toutes les ouvertures pour former un joi...

Страница 20: ...terrupteur qui commandera la lampe Retirer les deux vis une directement au dessus et une directement en dessous de l in terrupteur Etape 4 Ouvrir le couvercle de couvre interrupteur de lumi re Regent...

Страница 21: ...ns le premier mode NIGHT TIME ON s lectionn 2 heures 4 heures ou 6 heures m me si vous changez le r glage Laissez le dispositif sous tension Une fois Dur e d clairage de 4 Heures la Nuit Puis D tectio...

Страница 22: ...RE HORS CIRCUIT AVANT DE CONTINUER Est ce que le c blage du dispositif est desserr V rifier le c blage et reconnecter au besoin en utilisant les crous conducteurs fournis Est ce qu il y a du mouvement...

Страница 23: ...MODE CREPUSCULE A AUBE PENDANT LA NUIT ANNULATION LES LUMI RES NE S ALLUMENT PAS DANS LE MODE TIME ON DE NUIT LES LAMPES NE R PONDENT PAS AU R GLAGE DE LE MODE TIME ON DE NUIT La lumi re qui vient de...

Страница 24: ...t ne pas s appliquer votre cas Aucune autre garantie crite ou verbale n est autoris e par la Soci t Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez galement avoir d autres droit...

Отзывы: