4
ENGLISH
Step 9:
Apply silicone caulking around edges of coverplate and in any open holes to
provide a watertight seal from rain and moisture.
Step 10: Insert gaskets into lampholders and screw bulbs into each lampholder
(do not overtighten bulbs).
Step 11: Turn power on at main fuse/breaker box.
How to operate your fixture
Step 1:
Move slide switch on bottom of the sensor to
“TEST”. Set sensitivity slide switch to medium
or “M” (P).
Step 2:
Turn on the power to fixture. Allow fixture to warm
up approximately 90 seconds before testing. (Lights
may or may not come on during warm-up period,
this is normal.)
Step 3:
Aim sensor head in desired position. NOTE:
Maintain air spacing between lamps and sensor
head, at least 1”.
Make sure sensor head is
positioned with control switches facing towards
the ground.
Step 4:
Walk across the detection zone at the farthest
distance you wish your detector to detect motion.
Step 5:
Adjust sensitivity until you get desired results. For more range, aim sensor head
slightly upwards. For less range, aim sensorhead slightly downward. Lights will
turn off 4 seconds after all motion stops.
Step 6:
Move slide switch to 4 MIN or 12 MIN (AUTO mode), or to one of the three
“NIGHT TIME ON” settings. At dusk, lights will operate in the AUTO or Night
Time On settings.
Installing your light switch cover
This cover will only fit standard residential light switch toggles up to 1/4” wide. The light
switch cover prevents children and adults from accidentally turning off the power to this
Regetn light fixture. By inadvertently turning off the power, the mode of operation may be
changed. If the mode of operation needs to be changed, just flip up the light cover to find a
helpful guide at your fingertips with quick and easy instructions which will allow you to
select the mode of your choice.
NOTE: The modes of operation ONLY apply to this
motion light.
Step 1:
Turn off the power at the main fuse/breaker box.
Step 2:
Locate the inside light switch that will control
your motion activated light.
Step 3:
If you have a single light switch, remove the two
screws that are holding your current cover in
place.
NOTE: DO NOT REMOVE THE COVER.
The Regent light switch cover is designed to fit over your existing cover! If you
have a bank of light switches (several switches together), locate the one switch
that will control your motion light fixture. Remove the two screws, one directly
above and one directly below the switch.
Step 4:
Open the lid on your Regent light switch cover. Align the holes on the Regent
light switch cover over the holes in your current cover. Re-insert the screws to
secure it in place.
NOTE:
If your screws are not long enough, it may be neces-
sary for you to replace them with longer screws to secure the Regent light switch
cover over your existing cover.
Step 5:
Turn on the power at the main fuse/breaker box.
Step 6:
Turn the light switch to the “ON” position and close the lid on your light switch
cover.
TEST
4 MIN
M
12 MIN
2 HR
H
L
MODE
AUTO
SENSITIVITY
NIGHT TIME ON
6 HR
4 HR
Do not remove your
current cover.
Place over
existing cover
P