background image

If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

• Fixture must be connected to a 120 Volt, 60 Hz power source. Any other connection

voids warranty.

• Total wattage of light bulbs connected to the motion detector cannot exceed 300 watts

incandescent.

• This motion detector should be installed by persons with experience in household wiring

or by a qualified electrician. The electrical system, and the method of electrically connect-
ing the fixture to it, must be in accordance with the National Electrical Code and local
building codes.

• For proper operation and protection against damage, the motion sensor head adjustment

knobs must be facing the ground.

• Disassembly of your detector will void the warranty.
SAVE THESE INSTRUCTIONS.

For best results

• Install your fixture 8-12 feet above ground (motion detector is less

sensitive above 12 feet).

• Locate fixture so motion mo ves across detection zone (D).
• Locate fixture away from heat producing sources to prevent false

triggering. Also be very careful not to include objects such as 
windows, white walls and water in the detection zone whenever
possible.

• Locate fixture away from moving objects such as trees and

street traffic.

• Do not install more than one motion detector on one wall switch.

Assembling and wiring your motion detector 

Step 1:

Turn off the power at the main fuse/breaker box.

Step 2:

Screw motion detector arm into the desired hole on
junction box coverplate.

Step 3:

Attach all lampholders or light fixtures to the coverplate
as required by light fixture instructions .

Step 4:

Connect the wires together. Connect all white wires
together (house wire, detector wire, and lamp fixture
white wires) using wire nuts provided. Connect black
lamp wires to red wire from the detector. Connect
black house wire to black wire from the detector (E).

Step 5:

Attach fixture to the junction box according
to light fixture instructions.

Step 6:

Apply silicone caulking around the edges of
coverplate and in any open screw holes for
a watertight seal.

Step 7:

Insert bulb(s) according to light fixture
instructions.

Step 8:

Turn power on at main fuse/breaker box.

How to operate your fixture

Step 1:

Move slide switch on bottom of the sensor to “TEST”. Set sensitivity slide switch
to medium or “M” (halfway) (F).

3

D

E

Round        Rectangular (horizontal)     Octagonal

Your fixture mounts 

to the following standard 

junction boxes:

Содержание CMS240 MS240W

Страница 1: ...MS240 CMS240 MS240W CMS240W Instruction Manual Instrucciones Directives...

Страница 2: ...For outdoor use only UL and CSA LISTED for wet locations This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Страница 3: ...feet Locate fixture so motion moves across detection zone D Locate fixture away from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows whit...

Страница 4: ...to setting Lights should turn on with motion only at night and should turn off after 4 or 12 minutes of no motion AUTO 4 MIN or AUTO 12 MIN Keep the power to the fixture on Mode of operation Set slide...

Страница 5: ...nsor to How to set power switch 6 Hour NIGHT TIME ON then Motion Activated Lights should turn on automatically at night 100 brightness for 6 hours then reset to regular auto motion setting for the rem...

Страница 6: ...motion sensor in the test mode Move the switch to the AUTO 4 AUTO 12 or NIGHT TIME ON position Is the motion detector shadowed Reposition motion sensor Is the surrounding external ambient light too b...

Страница 7: ...LUDING IMPLIED WARRANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS EXPRESS WARRANTY Some states do not allow the exclusion or limitation...

Страница 8: ...odo de tiempo seleccionado o funcionar como un proyector est ndar sobrecontrol manual Qu se requiere Destornillador phillips Calafateo impermeable Placa de cierre de la caja de conexiones de 1 2 3 agu...

Страница 9: ...do por personas con experiencia en cableado dom sti co opor un electricista calificado El sistema el ctrico y el m todo utilizado para la conex i n el ctrica de este portal mparas al mismo debe regirs...

Страница 10: ...deseada Camine a trav s de la zone de detecci n tan lejos como desee que su detector registre movimiento NOTA Deje un espacio de aire de por lo menos 1 2 54 cm entre las l mparas y el sensor Aseg rese...

Страница 11: ...autom tica regular por el resto de la noche NIGHTTIMEON Encendido de noche 4 HR 4 Horas Nota Una vez que la luz se enciende en el modo de NIGHTTIMEON seleccionado no se puede reprogra mar hasta el am...

Страница 12: ...a posici n ON Aseg rese de que el foco no se haya quemado o roto Es la luz ambiental externa demasiado intensa Si es as la unidad actuar como si fuera de d a Redirija el cabezal Cambie la ubicaci n de...

Страница 13: ...rruptor que se encuentra en la parte inferior del sensor de movimiento en la modalidad de prueba Mueva el interruptor a la posici n AUTO 4 AUTO 12 NIGHTTIME ON Algo est dando sombra sobre el detector...

Страница 14: ...A UN PROPOSITO EN PARTICULAR ESTAN LIMI TADAS EN DURACION A LA DURACION DE LA GARANTIA EXPRESA En algunos estados no se permite la exclusi n o limitaci n de da os incidentales o consecuenciales o limi...

Страница 15: ...aux intemp ries Couvercle de bo te de jonction 1 2 ou 3 trous A Ce qui est compris dans cet ensemble D tecteur de mouvement B 3 Ecrous pour fil C Applications de montage communes pour mur et avant toi...

Страница 16: ...cifications du Code lectrique national ainsi que les r glementations locales pour le b timent Pour viter les dommages et obtenir un fonctionnement correct la t te du d tecteur doit faire face au sol...

Страница 17: ...vous d sirez que votre d tecteur soit sensible Etape 5 Ajuster la sensibilit jusqu ce que vous obteniez les r sultats d sir s Pour obtenir une plus grande port e relever l g rement le capteur Pour un...

Страница 18: ...e de 6 Heures la Nuit Puis D tection de Mouvement Les lumi res doivent s allumer automatiquement la nuit avec un clairage de 100 pour une dur e de 6 heures avant de retourner au mode d tection de mouv...

Страница 19: ...ouverte consulter le service client le L unit est elle dans le mode AUTO V rifiez que l unit n est pas dans l un des trois modes NIGHT TIME ON Est ce qu il y a du mouvement dans la zone de d tection V...

Страница 20: ...le de la Soci t et ceux caus s par la corrosion ou la d coloration des composants en laiton ne sont pas couverts par cette garantie Il n existe aucune garantie explicite autre que celle d crite ci des...

Отзывы: