P33CE-11 Direct Vent Gas Fireplace
installation
6-7/8"
(173mm)
dia. Flue pipe
4" (102mm)
dia. flue pipe
Wall Thimble (2 pc)
(required in
Canada only)
Termination Cap
(Part# 946-523/P)
AstroCap
TM
spring
spacer
Wherever necessary due to
external location of cap, the
AstroCap can be replaced with
the FPI Riser Vent Termination
Cap or the Dura-Vent Snorkel
Termination Cap.
Regency
®
Direct Vent Flex System
Horizontal Terminations Only
This venting system, in combination with the P33CE Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey/
Intertek. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .
Regency
®
Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33CE with a maximum run of 2 feet.
If install-
ing the P33E with a
continuous
vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 (10 ft) or see "Rigid Pipe
Venting Systems" Section for alternate venting arrangements.
1)
6-7/8" dia. flexible liner (2 ft. length)
2)
4" dia. flexible liner (2 ft. length)
3)
spring spacers (3)
4)
thimble (2)
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" drill point,
stainless steel (4)
See Figure 1 below for
Alternate Caps.
Notes:
1) Liner sections should be continuous
without any joints or seams.
2) Only Flex pipe purchased from Regency
®
may be used for Flex installations.
Minimum
Flex Kit Center-Line
Minimum
Rigid Pipe Center-Line
Alternate
Horizontal
Termination
Caps
Figure 1
Содержание Panorama P33CE-LP11