P33CE-11 Direct Vent Gas Fireplace
installation
Glass Door and Safety Screen Installation
Standard Flush Door
Both the standard flush door
comes with a black frame. Install the glass
door by hooking the top door flange onto the top of the unit and swing the door
towards the unit, Diagram 2. Be careful that the glass gasket does not roll up;
there must be a gap between the gasket and the door lip to ensure that the
door sits securely on the unit. See Diagram 3.
Use the hook to pull the spring out until you can put the hook into the slot on
the bottom door bracket. Repeat for 2nd spring. See Diagram 4.
To remove the flush door, reverse the above steps.
Diagram 3
Diagram 2
Diagram 1
Diagram 4
Safety Screen
1.
To remove the safety screen, grasp safety screen on both sides from the bot-
tom. Lift up and out slightly to release from bottom magnets and to release
hooks on mesh frame from brackets inside unit (see below).
Hooks on safety screen frame
2.
When hooks are clear of the bracket–tilt mesh frame out slightly from the
bottom and manoeuvre mesh out.
3.
To reinstall–reverse steps.