P33CE-11 Direct Vent Gas Fireplace
|
63
maintenance
Removing Valve
1.
Shut off the gas supply.
2.
Remove the safety screen and flush glass door–see instructions in
manual.
3.
Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the burner/
grate assembly.
4.
Remove the rear log stand by removing the 2 screws.
Installing Valve
1.
Install new valve assembly.
2. Reverse steps 7-1.
Diagram 5: Lift out Valve Tray Assembly
EV1
EV2
Ground
8.
Remove valve tray assembly.
7.
Remove the 12 screws securing the valve tray assembly in place
(Diagram 4) and then lift the entire assembly out.
Diagram 4 Valve Tray Assembly
Diagram 2
Diagram 3
Rear Log Stand
screws
5.
Disconnect the inlet gas line.
6.
Disconnect the EV1, EV2, and ground wires from the valve - as shown below.
Содержание Panorama P33CE-LP11
Страница 67: ...P33CE 11 Direct Vent Gas Fireplace 67 notes ...
Страница 72: ...72 P33CE 11 Direct Vent Gas Fireplace warranty ...
Страница 73: ...P33CE 11 Direct Vent Gas Fireplace 73 notes ...
Страница 74: ...74 P33CE 11 Direct Vent Gas Fireplace notes ...
Страница 75: ......