P33CE-11 Direct Vent Gas Fireplace
|
23
installation
29-7/16"
747mm
2
1
-3
/8
"
[5
4
2
m
m
]
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
No Combustible
Materials in this Area
3
3
-7
/1
6
"
[8
4
9
m
m
]
34-9/16"
878mm
2-1/2"
[64mm]
5-3/16"
[132mm]
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
3-1/2"
[89mm]
29-7/16"
747mm
2
1
-3
/8
"
[5
4
2
m
m
]
J Style trim or metal
corner bead may be
used to finish edges
No Combustible
Materials in this Area
1/2" DRYWALL
NON-COMBUSTIBLE FACING
FOR CLEAN LOOK
(ie. PAINTED FINISH)
34-9/16"
878mm
3
3
-7
/1
6
"
[8
4
9
m
m
]
1/2" DRYWALL
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT.
WOOD STUD
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
3-1/2"
[89mm]
7.
Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this
will assure ease of glass door removal and access to the lower panel.
NOTE:
Non-combustible finishing materials may be of any thickness desired.
Minimum Clearances for Finishing Materials
Trim Materials
Combustible and Non-combustible Facing and Finishing
Materials around unit.
Note:
All non-combustible facing material should butt up cleanly
to the flanges around the firebox opening.
Rough edges may be visible from an angle.
To maintain a clean finished edge - facing material edges
may be finished with a J-style trim or metal cornerbead (both
materials available at your local building or hardware store).
IMPORTANT:
Materials used must be NON-COMBUSTIBLE.
6.
If applying a non-combustible facing it may be installed over the metal surface of the firebox of the unit in the area shown below.
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into final position - it is important to know the
total thickness / height of finished hearth (tile, carpet, flooring etc.)
The Verona Surround or the Modera Mantel must be level to or higher
than the finished hearth height.
NoTE:
The 3-1/2" x 34-9/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non com-
bustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
Combustible
Material
Non-combustible
Finishing Material
Non-combustible Material (3-1/2" x 34-9/16")
Finishing Material
Nailing Strip -flush with unit
Combustible
Material
Non-combustible
Supplied with Unit
1-1/2
(38mm)
Ensure finished
material is
brought to lip
Non-Combustible Board Only (Painted Finish)