P33CE-11 Direct Vent Gas Fireplace
installation
Note: The logs must not be in the unit.
3)
Insert the back brick panel by carefully
slipping it between the back wall of the
firebox and the rear log bracket.
Optional Brick
Panels
1)
Remove the safety screen and glass door.
Remove logs.
2)
Attach the 2 Rear Brick Retaining clips to the
rear wall. Loosen the screws in the top and rear
wall of the firebox and slide the retaining clips
into position (tight against the firebox top) and
then tighten the screws.
4)
Put the side panels in next. Slide them in from
the front and push them flat up against the
wall. Be very careful not to scratch them on the
firebox hardware.
5)
Slide the Top Brick Panel into position and slide
the Top Brick Retaining clips so that they hold
the Top Brick Panel in place and tighten down
the screws.
Log Set Installation
Notch
Bracket
Bracket
250
254
Vermiculite
Vermiculite
Vermiculite
250
254
The 3-digit numbers (i.e. 250) are
molded into the rear of each log.
Read the instructions below carefully
and refer to the diagrams. If logs
are broken do not use the unit until
they are replaced. Broken logs can
interfere with the pilot operation.
Log Kit # 431-930 contains the
following pieces:
A) 250
Rear Log
B) 254
Middle Cross Log
C) 253
Front Left Cross Log
D) 251
Rear Left Log
E) 252
Front Right Cross Log
F)
Embers
902-156
G)
Vermiculite
902-179
H)
Rock Wool
902-153
I)
Platinum Embers 946-669
(supplied with packaged manual)
NOTE: If you will be installing the op-
tional Brick Panels, install the
Brick Panels prior to installing
the logs.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care -
do not force into position.
2) Sprinkle the vermiculite and embers around
the firebox base.
3) Place the Log 250 on the rear log support
pins with the flat side to the back.
4) Place Log 254 on the front right side of the
burner. Push the back of the log against
the 2 brackets with the notch on the bottom
right side of the log fitting into the right side
of the grate.
5) Position Log 253 across the cutouts in
Logs 250 and 254 with the notch on the
left side of the log fitting into the 2nd grate
tab.
Cutouts
2nd Grate Tab
253
250
254
D) 251
A) 250
C) 253
B) 254
E) 252
Содержание Panorama P33CE-LP11
Страница 67: ...P33CE 11 Direct Vent Gas Fireplace 67 notes ...
Страница 72: ...72 P33CE 11 Direct Vent Gas Fireplace warranty ...
Страница 73: ...P33CE 11 Direct Vent Gas Fireplace 73 notes ...
Страница 74: ...74 P33CE 11 Direct Vent Gas Fireplace notes ...
Страница 75: ......