30
|
City Series CB72EPV
installation
Clearances CB72EPV - Bay Install
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
fireplace and vent system be installed only in accordance with these instructions.
Flue Clearances to Combustibles
Horizontal - Top
3"
Horizontal - Side
2"
Horizontal - Bottom
2"
Vertical
2"
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2"
Note: This appliance uses 4" x 6-5/8" venting
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may
NOT
be
recessed into combustible construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
The
HeatWave
Duct Kit has differ-
ent clearance and framing require-
ments, check the
HeatWave
manual
for details.
E
F
B
Alcove
Clearance: single sided
Dimension
Measured From:
A1: Mantel Height (min.)
**
Top of Fireplace Opening
A: From Floor
min. 0"
Bottom of Fireplace Opening
B: Sidewall (on one side) Min.
8" (203mm)
Side of Fireplace Opening
C: Enclosure Width (min.)
82-11/16" (2100mm)
Minimum inside dimensions
D: Mantel Depth (max.)
**
E: Alcove Width
120" (3048mm)
Sidewall to Sidewall (Minimum)
F: Alcove Depth
36" (914mm)
Front to Unit (Maximum)
G: Convection Air Outlet Opening Offset
*0-2" (0-51mm)
Max. offset from top of chase enclosure
H: Convection Air Outlet
*288 square inches
I Enclosure Depth (min.)
20-3/8" (517mm)
Minimum inside dimensions
J: Opening Height
15-1/16" (383mm)
Bottom/Top of Fireplace Opening
K: To Ceiling (Min.) all 3 sides
2-1/2" (64mm)
To Top of Ceiling
L: Chase Enclosure (Min.)
87" (2210mm)
From base of unit/floor to top of enclosure
M:
Clearance to Sprinkler Head (Min.)
36" (914mm)
Perpendicular from chase grill
Hearth
0"
No hearth required
**
See mantel clearances chart in this manual.
L
Chase grill
Sprinkler
Side view
M
Содержание City CB72EPV-LP
Страница 113: ...City Series CB72EPV 113 notes ...
Страница 118: ...118 City Series CB72EPV ...
Страница 119: ......