34
|
City Series CB72EPV
installation
Framing Dimensions CB72EPV - Bay Install
NOTE:
Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing
Dimensions
Description
CB72EPV
A
Framing Height
51" (1295mm)
B
Framing Width
82-11/16" (2100mm)
C*
Framing Depth
20-5/8" (524mm)
D
Minimum Height to Combustibles
87"(2210mm)
G
Vent Centerline Height
55-1/4" (1403mm)
**
Gas Connection Opening Height
See gas connection location in this manual
**
Gas Connection Height
See gas connection location in this manual
**
Gas Connection Inset-Centre Opening
See gas connection location in this manual
C* - see not in diagram below
** See manual for alternate Gas/ Electrical connection options
Note: A combined minimum
of 288 square inches of open
area is required for the con-
vection air outlet to cool the
enclosure. Ensure clearances
for Convection Air Outlets
are met.
See clearances CB72EPV in
this manual as there are dif-
ferent methods as to how this
can be achieved.
Note: This appliance must be
installed on a solid surface
such as a plywood floor
which must be the full width
and depth of the appliance.
Ensure that the wood base that the appliance will sit on is strong enough to support the full weight of this appliance.
The overall weight of this appliance is 582 pounds (shipping weight).
Note: Unit must be installed onto a solid
backwall - do not install directly onto studs.
*C
Note :
The framing depth does not take into
account drywall/wood or similar materials
against the back wall. The framing depth will
need to change based on the thickness of
the material (example: 20 5/8 framing depth
+ 1/2 drywall = 21 1/8")