City Series CB72EPV
|
49
installation
Framing and Finishing Inset Installations CB72EPV
1. Frame in the enclosure for the unit with framing material
Note:
When constructing the framed opening ensure there is access to install
the gas lines,electrical. Also the wiring harness must be wall mounted using
the receptacle provided with the appliance. The wiring harness will be located
on the right hand side of the appliance if facing the unit from the front. This
must be done prior to any finishing.
2. For exterior walls, insulate the enclosure to the same degree as the rest of
the house, apply vapour barrier and drywall, as per local installation codes.
(Do not insulate the fireplace itself.)
WARNING:
Failure to insulate and add vapor barriers to the inside of the
exterior wall will result in operational and performance problems including, but
not limited to: excessive condensation on glass doors, poor flame package,
carbon, blue flames etc. These are not product related issues.
3. To ensure the chase is sealed from the outside wall into the room, all joints
on the facing wall
MUST
be sealed, mudded, and taped to finish.
Note that in all applications while there is a zero clearance to combustibles
to the unit, all clearances to combustibles from the venting inside the chase
still applies. Please see venting clearances in the specific product manual.
4. Combustible material (drywall,wood,wood panels, etc.) may be brought up
to the appliance (top,bottom and sides)
5. Ensure that the material being used does not encroach anywhere in the
area of the glass. This would cause dangerous operating conditions.
6. This appliance comes with a 1/2" lip at top and bottom to hide the ends of
the drywall. The 1/2" side and bottom lip supplied with the appliance can
alternatively be removed (see Diagram 1) and replaced with J Style Trim
or Metal Corner Bead purchased at your local hardware store to cover cut/
exposed edges of the combustible facing material or any other finishing
materials being used. 6 screws secure the bottom lip — see Diagram 1.
These will be hidden so the outer panels will need to be removed to access
the screws. See outer panel removal in this manual.
7. This appliance can also be recessed (using combustible materials) with
a hearth in front of the appliance. This can also extend to the top. See
manual for details.
Содержание City CB72EPV-LP
Страница 113: ...City Series CB72EPV 113 notes ...
Страница 118: ...118 City Series CB72EPV ...
Страница 119: ......