28
|
CV40E-11 City Series
installation
Chase Venting
CHASE VENTING
A minimum
120
in
2
opening in the enclosure is required to maintain safe operating
temperatures. This can be achieved in a number of ways including the examples shown below.
Warning: DO NOT cover or place objects in front of the air outlet(s).
Regency Chase Vent
Dimensions:
3.2
”x
40
”
(81 mm x 1016 mm)
(
130
in
2
)
Custom chase vent
Example dimensions: 2.5”x
48
”
(64 mm x 1219 mm)
(
120
in
2
)
Reveal at the chase top
Example dimensions: 2”x
60”
(51 mm
x 1524 mm)
(
1
20in
2
)
Venting into an adjacent room
Minimum
120
in
2
Note: An adjacent room cannot be a garage/closed in carport.
Note: The enclosure opening cannot be any lower than 0-3" from the top of the enclosure for all installations. Minimum height of enclosure
from base of appliance is 63".
Содержание CB40E-LP11
Страница 79: ...CV40E 11 City Series 79 parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Страница 84: ...84 CV40E 11 City Series warranty ...
Страница 85: ...CV40E 11 City Series 85 notes ...
Страница 86: ...86 CV40E 11 City Series notes ...
Страница 87: ...CV40E 11 City Series 87 ...