Outer Safety Glass Panel (Barrier Glass) Installation / Removal
The outer glass safety panel to be installed during the initial installation after
the unit is in the final position.
Note
: The outer safety panel comes with plastic corners to protect these against
damage. These should be kept in place until such time the outer safety panels
are installed. Ensure these are removed prior to operating the appliance. Keep
the plastic corners in a safe place if ever removing the outer panels for servicing.
1. Carefully remove glass safety panels from packaging.
3. Tilt the top of the glass panel inward and lift up and underneath
the upper front panel of the outside frame. Hook the glass panel
onto the pins and also onto the two angle adjustment brackets lo-
cated on the frame in two locations as shown in the diagram below.
Note:
The front frame upper panel is shown as transparent to better
illustrate the install (this area is not visible when installing glass).
Press glass vacuum clamp in open position firmly onto surface of glass. Bring
handles together to close.
Open
Closed
NOTE:
Inner glass panel shown in image - depicting proper handling
of glass.
WARNING: GLASS HANDLING
We recommend using the glass vacuum holders supplied by the manufac-
turer. Lower the glass to rest in a safe place, this is to prevent damage to the
glass edges. Extra care must be taken when removing/installing the glass.
Breakage or damage to the edge of the glass which occurs as a result of
careless handling will not be covered under warranty.
•
We recommend handling the glass with supplied vacuum
clamps
• When removing glass–prepare a soft, scratch resistant
surface to place the glass
• Never clean or remove hot glass
Note: The suction cups may leave a round film on the glass
when used. Ensure that the glass is cleaned using a fireplace
glass cleaner prior to operating the appliance.
Note:
If the outer safety glass panel does not sit at 90
º
and angles too far
inward or outward, remove the glass panel and adjust the screw of
the panel angle bracket. Turn the panel angle bracket screw in 1/4
increments—reinstall panel to check.
Angle adjustment brackets
Pins on body of unit
Panel angle bracket—to
adjust, turn screw:
Clockwise = bring panel in
Counter clockwise= bring
panel out
2. Using the supplied vacuum clamps, lift the large front glass panel and
position it front and centre by manoeuvering up and underneath the front
of the unit frame.
Note:
safety glass panels must be installed to operate fireplace
To watch the safety barrier glass installation video click
here
.
Содержание CB40E-LP11
Страница 79: ...CV40E 11 City Series 79 parts list 7 8 9 2 1 3 6 4 5 12 17 27 19 20 18 22 6a 26 24 23 25 11 ...
Страница 84: ...84 CV40E 11 City Series warranty ...
Страница 85: ...CV40E 11 City Series 85 notes ...
Страница 86: ...86 CV40E 11 City Series notes ...
Страница 87: ...CV40E 11 City Series 87 ...