 U39-12 ULTIMATE™ Freestanding Gas Stove

  |     

5

safety decal

This is a copy of the label that accompanies each 
ULTIMATE Direct Vent Freestanding Gas Stove. We 
have printed a copy of the contents here for your 
review. The safety label is located on the inside of 
the drop down pedestal door. 

NOTE:

  Regency

®

  units  are  constantly  being 

improved. Check the label on the unit and if there is 
a difference, the label on the unit is the correct one.

Copy of Safety Label for U39 Gas Stove

Minimum Clearances  to Combustibles 

Dégagements minimaux aux matériaux combustibles

532

Serial No./No de série

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

 

A  7-1/2"  /190mm

B  6" 

/150mm

E  2"  

/50mm

Min. Ceiling Height from top of unit / Min. Plafond  

Hauteur depuis le haut de l'appareil: 

36" / 914 mm 

Duplicate serial #

M

od

el/M

od

èle

 : 

U3

9-N

G

12

M

od

el/M

od

èle

 : 

U3

9-L

P12

532

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

Refer to Intertek's Directory of Building Products for detailed information.

Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.

 

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.

This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 

24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 

501C Standard for Recreational Vehicles

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited 

by local codes. See owner's manual for details. Optional Fan (Part# 910-331/P).

Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.

Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construc-

tion and Safety Standard. Si ces normes ne sont pas pertinentes, se reporter à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou 

NFPA 501C Standard for Recreational Vehicles.

Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée mobile installée à demeure si les 

règlements locaux le permettent. Voir le manuel d'utilisation pour plus de renseignements. Ventilateur en option (Pièce n

o

910/331/P)

This vented gas fi replace heater is not for use with air fi lters.          N e pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation

.                                                   

                                       

For use with glass doors certifi ed with the appliance only               À utiliser uniquement avec les portes vitrées certifiées avec l’appareill

          

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. 

FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE

.

Made in Canada / Fabriqué au Canada

Listed: VENTED GAS FIREPLACE HEATER  / FOYER AU GAZ À ÉVACUATION

Certifi ed to/Certifi é : 

C# 4001172

For Use Only with Barrier (Part #732-929) Follow installation instructions.

Utiliser uniquement avec l’écran de sécurité (n° 732-929). Suivre les consignes d'installation.

ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE

115V_60HZ less than/Moins de 2 AMP.

FPI Fireplace Products International Ltd. Delta, BC, Canada

 

FACTORY EQUIPPED FOR NATURAL GAS:

 Model U39-NG12

Minimum supply pressure 

5" 

WC/C.E. (1.25kPa)

Manifold pressure High 

3.5"     WC/C.E. (0.87kPa)

Manifold pressure Low 

1.6" 

WC/C.E. (0.40kPa)

Model U39-NG12: Factory Equipped for Altitude 0-2000 ft.
Orifi ce size 

#32 

DMS

Altitude 

0-2000  ft/pi 

(0-610)

Maximum Input 

38,000   Btu/h  (11.1Kwh)

Minimum Input 

26,000  Btu/h  (7.61Kwh)

Model U39-NG12: Convertible for Altitude 0-4500 ft.

Orifi ce size 

#35 

DMS

Altitude 

0-4500   ft/pi          (0-1370m)

Maximum Input 

35,000   Btu/h  (10.26Kw)

Minimum Input 

24,000  Btu/h  (7.03Kwh)

FACTORY EQUIPPED FOR PROPANE GAS: 

Model U39-LP12

Minimum supply pressure 

11" 

WC/C.E. (2.74Kpa)

Manifold pressure High 

10" 

WC/C.E. (2.49Kpa)

Manifold pressure Low 

6.4" 

WC/C.E. (1.59Kpa)

Orifi ce size 

49 

DMS

Altitude 

0-2,000  ft/pi 

(0-610m)

Maximum Input 

38,000  BTU/h  (11.1Kw/h)

Minimum Input 

30,000  BTU/h  (8.79Kw/h)

Model U39-LP12: Convertible for Altitude 0-4500 ft.

Orifi ce size 

#51 

DMS

Maximum Input 

32,500   Btu/h  (9.52Kwh)

Minimum Input 

26,000  Btu/h  (7.61Kwh)

APPAREIL FONCTIONNANT AU GAZ NATUREL : 

Modèle U39-NG12

Pression d’alimentation minimale 

Pression manifold élevée

Pression manifold basse

Fonctionnant à une altitude entre 0 et 2000 pi :

Dimensions de l’orifi ce

Altitude

Débit calorifi que maximal

Débit calorifi que minimal
Convertible pour altitude entre 0 et 4500 pi :

Dimensions de l’orifi ce

Altitude

Débit calorifi que maximal

Débit calorifi que minimal

APPAREIL FONCTIONNANT AU PROPANE : 

Modèle U39-LP12

Pression d’alimentation minimale

Pression manifold élevée

Pression manifold basse

Dimensions de l’orifi ce 

Altitude

Débit calorifi que maximal

Débit calorifi que minimal

Convertible pour altitude entre 0 et 4500 pi :

Dimensions de l’orifi ce

Débit calorifi que maximal

Débit calorifi que minimal

                    

920-134

CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1

Natural Gas / Gaz naturel 71.45%

Propane Gas / Gaz propane 74.31%

CANADIAN ENERGY 

PERFORMANCE 

VERIFIED

RENDEMENT 

ÉNERGÉTIQUE 

VÉRIFIÉ

EP5011169

Part #: 920-134

Colour:      Black on Grey except selected text

                  is in red as per this print.

Material:    2ml silver matt polyester (DPM SMS)

Size:          100%

June 26/19: Created Decal

* Printer: Start serial sequence at 532000001

ANSI Z21.88-2017 • CSA 2.33-2017 / CSA 2.17-2017

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth 
of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm 
with battery back up in the same room where the gas appliance is installed.

Содержание U39-NG12

Страница 1: ...ilding immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and se...

Страница 2: ...d by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now t...

Страница 3: ...ertical Terminations 24 Cathedral Ceilings 25 Converting a Class A Metal Chimney to a Direct Vent System 26 System Data 27 Gas Connection 27 High Elevation 27 Conversion from NG to LP 28 Conversion to...

Страница 4: ...39 12 ULTIMATE Freestanding Gas Stove dimensions ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 913 16 250mm...

Страница 5: ...s vitr es certi es avec l appareill VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUELS FOYER AU GAZ VACUATION NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE Made in Canada Fabriqu au Canada Listed V...

Страница 6: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 7: ...it converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply wi...

Страница 8: ...the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed...

Страница 9: ...E KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY A...

Страница 10: ...es for servicing proper operation and around the air openings into the combustion chamber 2 The appliance may be installed on a flat solid continuoussurface e g wood metal concrete This may be the flo...

Страница 11: ...onnected to the specifiedventandterminationcaptotheoutside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per the instructions starting i...

Страница 12: ...balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingthen...

Страница 13: ...ended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other...

Страница 14: ...ack N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A...

Страница 15: ...onal for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Ve...

Страница 16: ...nents WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems When using Rigid Vent other than Simpson D...

Страница 17: ...ways maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Be sure to check the vent termination clearance requirements from de...

Страница 18: ...The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontalterminations Maximumone90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Reside...

Страница 19: ...total vertical and maximum 4 feet total horizontal Please note minimum 1 foot between 90o elbows is required Lengthsdonotincludeelbowindicated One 90o elbow Two 45o elbows Option V H V1 V V1 A 1 Min...

Страница 20: ...desired location Check to determine if wall studs will be in the way of the venting system adjust location until all clearances are met and there are no obstructions Note A1 1 2 38mm clearancearoundth...

Страница 21: ...3 of the 8 x 1 2 black screws Pipe seams should be facing the wall 16 Attach the 90o elbow onto the pipe section by sealing with Mill Pac and securing with 3 of the 8 x 1 2 screws black 17 Slide the a...

Страница 22: ...it flue outlet to the ceiling the ceiling thickness the vertical rise in an attic or second storey and allowforsufficientverticalheightabovetheroofline Formulti storeyapplications firestopsarerequired...

Страница 23: ...e terminated If the wall being penetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable Diagram 3 Dura Vent Horizontal Terminations 1 Set the...

Страница 24: ...concealed by the decorative wall thimble cover See diagram 6 4 If installing the vent termination to a wall with vinyl siding the Vinyl Siding Standoff must be used Attach the Vinyl Siding Standoff to...

Страница 25: ...in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashing until the hei...

Страница 26: ...least a 2 inch overlap where the extension joins the support General Prior to installation and connection of the vent system to a Class A chimney the chimney must be inspected and thoroughly cleaned b...

Страница 27: ...rt 730 920 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 In U S A for installations above 2000 ft refer to current ANSI Z223 1 Sc8 8 1 2a appendix F for resizing orifice Sy...

Страница 28: ...fice in the kit 11 Reinstall new burner orifice LPG stamped 49 and tighten 13 Check for gas leaks with a proper soapy solution or leak detector 14 Check for proper spark between the ignitor and pilot...

Страница 29: ...ten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION 920 1...

Страница 30: ...n use the Allen key to turn the turning gear which will adjust the air shutter Open the air shutter for a blue flame or close it for a yellow flame Note Any damage due to carboning resulting from impr...

Страница 31: ...pport A B 3 Place the Middle Left Log B on the two pins as shown The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Fro...

Страница 32: ...urner tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible b...

Страница 33: ...burner to the other If there is any flame hesitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45 A 02 65 G 02 48 D 0 2 4 6 B 02 56 C 02 44 11 Using the harder coal like ember...

Страница 34: ...dle Left Log B on the two pins as shown The driftwood log kit contains the following A Rear Log B Middle Left Log C Front Left Log D Left Top Log E Front Right Log F Center Log G Middle Right Log C 4...

Страница 35: ...tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible burner...

Страница 36: ...ows smoothly from one end of burner to the other If there is any flame hesitation check that area for any burner port blockage 11 Using the harder coal like embers carefully spread these around the OU...

Страница 37: ...ngpowertothereceptaclebox provided with the unit in case the fan is installed at a later date Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Labelall...

Страница 38: ...adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooti...

Страница 39: ...ery difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot Proflame vid eo DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE NOTE This appliance will operate...

Страница 40: ...can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas su...

Страница 41: ...in the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the...

Страница 42: ...PROFLAME Transmitter Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Low battery alarm Child safety lock out Room Temperature Aux ON Set Point Temperature Level State Flame ON Th...

Страница 43: ...il the desired set temperature is dis played on the LCD screen of the Transmitter Remote Flame Control The Proflame GTMF has six 6 flame levels With the system on and the flame level at the maximum in...

Страница 44: ...peration Toactivatethisfunction presstheMODEandUPKeysatthesametime fig 18 To de activate this function press the MODE and UP Keys at the same time Low Battery Power Detection Transmitter The life span...

Страница 45: ...condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place or with the door open 8 Periodically ch...

Страница 46: ...er warranty Door Gasket If the door gasket requires replacement use 7 8 diameter oval door gasket Part 732 570 Latch Adjustment The door latch may require adjustment as the door gasket material compre...

Страница 47: ...move the grounding prong from this plug To Remove U39 Fan from front of Unit 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log support then remove the 10 screws holding t...

Страница 48: ...ant to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint 2 Remove 2 screws to remove receiver cover 3 Remove chain from door and unit remove...

Страница 49: ...licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can...

Страница 50: ...ouver Assy Black 9 732 513 Relief Door Assembly 10 732 022 Mounting Plate Gasket 11 730 517 P Fan Assembly 910 331 P Fan Motor 120 Volt 12 910 813 Power Cord 120 Volt 15 Pedestal Assembly 16 730 039 P...

Страница 51: ...08 Gasket Burner Tray Firebox 78 734 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 82 630 009 Gasket Burner Tray Air Passage 84 Air Shutter Gear Asse...

Страница 52: ...scription 209 732 943 Black Wrap Door Complete 732 944 Brushed Nickel Wrap Door Complete 101 732 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre Paper 208 940 325 P...

Страница 53: ...Regency U39 12 ULTIMATE Freestanding Gas Stove 53 notes...

Страница 54: ...ontrol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystal...

Страница 55: ...rafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of r...

Страница 56: ...the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authori...

Страница 57: ...w in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product...

Страница 58: ......

Страница 59: ......

Страница 60: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Отзывы: