background image

 

Regency

®

 U39-12 ULTIMATE™ Freestanding Gas Stove

  |     

11

installation

Installation  
Checklist

1.  Locate your appliance. Refer to the following 

sections: 

 

a. Locating Your Ultimate Gas Stove

 

b. Exterior Vent Termination Locations

 

c. Clearance to Combustibles

 

d. Combustion and Ventilation Air

2.  Install Louvers.  Refer to the "Louver Installation" 

section.

3.  Choose a venting option and install accordingly.  

Refer to the following sections where applicable: 

 

a. DV Stove Horizontal Vent Kit

 

 

    Installation

 

b. Dura-Vent Termination Kit

 

c. Converting a Class-A Metal Chimney  
    to a Direct Vent system.

4.   Install 4-AA batteries into receiver. This will
 

enable operation of appliance manually

 

when in "ON" position.

5.  Make  gas  connections.  Refer  to  "Gas 

Connection" section. 

 

Test the pilot. Must be as per diagram. Refer to 
"Pilot Adjustment" section.

6.  If necessary, see the "Conversion from NG to 

LPG" section and "Conversion to Lower BTU 
Rating" section.

7.  Test Gas Pressure. Refer to "Gas Pipe Pressure 

Testing" section .

8.  Install standard and optional features.  Refer to 

the following sections where applicable: 

 

a. Log Set

 

b. Front Door

 

c. Wall Thermostat

 

d. Remote Control

 

e. Safety Screen

 

f.  Louver Installation

 

g. 1-AA battery into DC spark box

 

h. 4-AA batteries into remote receiver

9.  Final check.  Refer to the "Final Check" section.

General Safety  
Information

1.  The appliance installation must conform with 

local Canadian Electrical Code.

2.  The  appliance  when  installed,  must  be 

electrically grounded in accordance with local 
codes, or in the absence of local codes with the 
current National Electrical Code, ANSI/NFPA 70 
or CSA C22.1 Canadian Electrical Code.

3.  The  appliance should be inspected for shipping 

damage before use and 

serviced annually by 

a professional service person

. More frequent 

cleaning  may  be  required  due  to  excessive 
lint  from  carpeting,  bedding  material,  etc.  It 
is imperative that control compartments, and 
circulating  air  passageways  of  the  appliance 
be kept clean and free from excessive lint from 
carpeting.

4.  See  general  construction  and  assembly 

instructions. The appliance and vent should be 
enclosed when installed in or passing through a 
living area, where children may come in contact 
with it.  

5.  This  appliance  must  be  connected  to  the 

specified vent and termination cap to the outside 
of the building envelope. Never vent to another 
room or inside a building.  Make sure that the 
vent is fitted as per the instructions starting in 
"Locating Your Ultimate Gas Stove" section.

6.  Inspect the venting system annually for blockage 

and any signs of deterioration.   

7.  Venting terminals shall not be recessed into a 

wall or siding.

8.  Any safety glass removed for servicing must be 

replaced prior to operating the appliance.  

9.  To prevent injury, do not allow anyone who is  

unfamiliar with the operation to use the fireplace.  

Before  leaving  this  unit  with  the  customer,  the 
installer  must  ensure  that  the  appliance  is  firing 
correctly  and 

operation fully explained to 

customer

.

This includes:
1.

  Clocking the appliance to ensure the correct 

firing rate (rate noted on label) after burning 
appliance for 15 minutes.

2.

  If required, adjusting the primary air to ensure 

that the flame does not carbon. First allow the 
unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.

Clearances To  
Combustibles

The  clearances  listed  are  MINIMUM  distances. 
Measure the clearance to both the appliance and 
the chimney connector. 

The farthest distance is 

correct if the two clearances do not coincide.

 

For example, if the appliance is set as indicated in 
one of the figures but the connector is too close, 
move the stove until the correct clearance to the 
connector is obtained.  

This  appliance  may  be  installed  only  with  the 
clearances  as  shown  in  the  situations  pictured. 

Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances.

This unit can be installed on a solid combustible 
surface  like  a  wood  floor. This  unit  can  also  be 
installed directly on carpeting  or vinyl when the 
bottom  pedestal  cover  plate  (provided  with  unit) 
is installed.

Use the minimum clearances shown in the diagrams 
below:

U39-NG12 & U39-LP12 Clearances

A  Side Wall to Unit 

7-1/2" / 190 mm

B  Back Wall to Unit 

6" / 150 mm

E  Side Wall to Unit 

2" / 50 mm

U39-NG12 & U39-LP12 Reference 

Dimensions

C  Back Wall to Flue Centerline  11"/280 mm
D  Side Wall to Flue Centerline 20-1/2"/521 mm
F  Side Wall to Flue Centerline  11"/280 mm
Minimum ceiling height is 36" / 914 mm from top 
of unit.

Vent pipe clearances to combustibles1-1/4” (32mm)

Содержание U39-NG12

Страница 1: ...ilding immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and se...

Страница 2: ...d by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now t...

Страница 3: ...ertical Terminations 24 Cathedral Ceilings 25 Converting a Class A Metal Chimney to a Direct Vent System 26 System Data 27 Gas Connection 27 High Elevation 27 Conversion from NG to LP 28 Conversion to...

Страница 4: ...39 12 ULTIMATE Freestanding Gas Stove dimensions ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS 913 16 250mm...

Страница 5: ...s vitr es certi es avec l appareill VENTED GAS FIREPLACE HEATER NOT FOR USE WITH SOLID FUELS FOYER AU GAZ VACUATION NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE Made in Canada Fabriqu au Canada Listed V...

Страница 6: ...irectly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT D...

Страница 7: ...it converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply wi...

Страница 8: ...the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed...

Страница 9: ...E KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY A...

Страница 10: ...es for servicing proper operation and around the air openings into the combustion chamber 2 The appliance may be installed on a flat solid continuoussurface e g wood metal concrete This may be the flo...

Страница 11: ...onnected to the specifiedventandterminationcaptotheoutside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per the instructions starting i...

Страница 12: ...balanced flue technology Co Axial system The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingthen...

Страница 13: ...ended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other...

Страница 14: ...ack N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A...

Страница 15: ...onal for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Ve...

Страница 16: ...nents WARNING Do not combine venting components from different venting systems However use of the the AstroCapTM and FPI Riser is acceptable with all systems When using Rigid Vent other than Simpson D...

Страница 17: ...ways maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Be sure to check the vent termination clearance requirements from de...

Страница 18: ...The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontalterminations Maximumone90O elbow two 45o elbows equal one 90o elbow Propane and Natural Gas Reside...

Страница 19: ...total vertical and maximum 4 feet total horizontal Please note minimum 1 foot between 90o elbows is required Lengthsdonotincludeelbowindicated One 90o elbow Two 45o elbows Option V H V1 V V1 A 1 Min...

Страница 20: ...desired location Check to determine if wall studs will be in the way of the venting system adjust location until all clearances are met and there are no obstructions Note A1 1 2 38mm clearancearoundth...

Страница 21: ...3 of the 8 x 1 2 black screws Pipe seams should be facing the wall 16 Attach the 90o elbow onto the pipe section by sealing with Mill Pac and securing with 3 of the 8 x 1 2 screws black 17 Slide the a...

Страница 22: ...it flue outlet to the ceiling the ceiling thickness the vertical rise in an attic or second storey and allowforsufficientverticalheightabovetheroofline Formulti storeyapplications firestopsarerequired...

Страница 23: ...e terminated If the wall being penetrated is constructed of non combustible material i e masonry block or concrete a 7 diameter hole is acceptable Diagram 3 Dura Vent Horizontal Terminations 1 Set the...

Страница 24: ...concealed by the decorative wall thimble cover See diagram 6 4 If installing the vent termination to a wall with vinyl siding the Vinyl Siding Standoff must be used Attach the Vinyl Siding Standoff to...

Страница 25: ...in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashing until the hei...

Страница 26: ...least a 2 inch overlap where the extension joins the support General Prior to installation and connection of the vent system to a Class A chimney the chimney must be inspected and thoroughly cleaned b...

Страница 27: ...rt 730 920 For Natural Gas installations above 4500 ft follow current CAN CGA B149 1 In U S A for installations above 2000 ft refer to current ANSI Z223 1 Sc8 8 1 2a appendix F for resizing orifice Sy...

Страница 28: ...fice in the kit 11 Reinstall new burner orifice LPG stamped 49 and tighten 13 Check for gas leaks with a proper soapy solution or leak detector 14 Check for proper spark between the ignitor and pilot...

Страница 29: ...ten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION 920 1...

Страница 30: ...n use the Allen key to turn the turning gear which will adjust the air shutter Open the air shutter for a blue flame or close it for a yellow flame Note Any damage due to carboning resulting from impr...

Страница 31: ...pport A B 3 Place the Middle Left Log B on the two pins as shown The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Fro...

Страница 32: ...urner tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible b...

Страница 33: ...burner to the other If there is any flame hesitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45 A 02 65 G 02 48 D 0 2 4 6 B 02 56 C 02 44 11 Using the harder coal like ember...

Страница 34: ...dle Left Log B on the two pins as shown The driftwood log kit contains the following A Rear Log B Middle Left Log C Front Left Log D Left Top Log E Front Right Log F Center Log G Middle Right Log C 4...

Страница 35: ...tray E Bracket The bottom right edge of Log G must sit snugly against the bracket Side View G 9 TaketheEmbaglow steelwoollikematerial lightlyseparate it and set a small amount over the visible burner...

Страница 36: ...ows smoothly from one end of burner to the other If there is any flame hesitation check that area for any burner port blockage 11 Using the harder coal like embers carefully spread these around the OU...

Страница 37: ...ngpowertothereceptaclebox provided with the unit in case the fan is installed at a later date Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Labelall...

Страница 38: ...adjusting the primary air to ensure that the flame does not carbon First allow the unit to burn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooti...

Страница 39: ...ery difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot Proflame vid eo DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE NOTE This appliance will operate...

Страница 40: ...can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas su...

Страница 41: ...in the unit these sounds will likely re occur Again this is normal for steel fireboxes Blower Thermodisc When this thermally activated switch turns ON it will create a small clicking sound This is the...

Страница 42: ...PROFLAME Transmitter Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Low battery alarm Child safety lock out Room Temperature Aux ON Set Point Temperature Level State Flame ON Th...

Страница 43: ...il the desired set temperature is dis played on the LCD screen of the Transmitter Remote Flame Control The Proflame GTMF has six 6 flame levels With the system on and the flame level at the maximum in...

Страница 44: ...peration Toactivatethisfunction presstheMODEandUPKeysatthesametime fig 18 To de activate this function press the MODE and UP Keys at the same time Low Battery Power Detection Transmitter The life span...

Страница 45: ...condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place or with the door open 8 Periodically ch...

Страница 46: ...er warranty Door Gasket If the door gasket requires replacement use 7 8 diameter oval door gasket Part 732 570 Latch Adjustment The door latch may require adjustment as the door gasket material compre...

Страница 47: ...move the grounding prong from this plug To Remove U39 Fan from front of Unit 1 Unplug or disconnect power source to stove 2 Remove all logs and the rear log support then remove the 10 screws holding t...

Страница 48: ...ant to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint 2 Remove 2 screws to remove receiver cover 3 Remove chain from door and unit remove...

Страница 49: ...licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can...

Страница 50: ...ouver Assy Black 9 732 513 Relief Door Assembly 10 732 022 Mounting Plate Gasket 11 730 517 P Fan Assembly 910 331 P Fan Motor 120 Volt 12 910 813 Power Cord 120 Volt 15 Pedestal Assembly 16 730 039 P...

Страница 51: ...08 Gasket Burner Tray Firebox 78 734 550 Burner Assembly NG LP 80 260 565 Air Shutter Gear Assembly Female 81 904 565 Hex Key 3 16 AF 82 630 009 Gasket Burner Tray Air Passage 84 Air Shutter Gear Asse...

Страница 52: ...scription 209 732 943 Black Wrap Door Complete 732 944 Brushed Nickel Wrap Door Complete 101 732 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre Paper 208 940 325 P...

Страница 53: ...Regency U39 12 ULTIMATE Freestanding Gas Stove 53 notes...

Страница 54: ...ontrol Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystal...

Страница 55: ...rafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of r...

Страница 56: ...the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authori...

Страница 57: ...w in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product...

Страница 58: ......

Страница 59: ......

Страница 60: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ________________________________________________...

Отзывы: