Regency
®
U39-12 ULTIMATE™ Freestanding Gas Stove
|
19
installation
Horizontal Venting with Two (2) 90
o
Elbows
Vertical Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows
Option
V
H + H1
A)
3' Min.
2' Max.
B)
5' Min.
3' Max.
C)
8' Min.
4' Max.
With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90
o
elbows is required.
Lengths do not include elbow indicated
One 90
o
elbow = Two 45
o
elbows
Option
V
H
V1
V + V1
A)
1' Min.
1' Max.
1' Min.
2' Min.
B)
1' Min.
2' Max.
2' Min.
3' Min.
C)
2' Min.
3' Max.
2' Min.
4' Min.
D)
2' Min.
4' Max.
2' Min.
4' Min.
With these options, max. total pipe length is 30 feet with
min. of 4 feet total vertical and max. 4 feet total horizontal.
Please note min. 1 foot between 90
o
elbows is required.
Lengths do not include elbow indicated
.
Содержание U39-NG12