12
|
Regency
®
U39-12 ULTIMATE™ Freestanding Gas Stove
installation
For Vent Termination requirements, see "Exterior
Vent termination Locations" section.
Louver
Installation
Attach the top & bottom louvers to the side stove
panel using 2 screws per side.
D
F
C
Manufactured Mobile Home
Additional Requirements
1.
Ensure that structural members are not cut or
weakened during installation.
2.
Ensure proper grounding using the #8 ground
lug provided.
3.
Appliance must be anchored to the floor
with the supplied anchoring methods.
Locating Your Gas Stove
When selecting a location for your stove, ensure
that the clearances listed above are met as well
as ensuring that there is adequate accessibility for
servicing and proper operation.
A) Cross Corner
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/ Alcove
Venting
Introduction
The DV Stove Horizontal Vent Kit and the
Simpson Dura-Vent Direct Vent, venting systems,
in combination with the ULTIMATE Direct Vent
Freestanding Gas Stove, U39-NG12, and U39-
LP12, have been tested and listed as direct vent
heater systems by Intertek. If converting a Class-A
Metal Chimney to a Direct Vent system, see
instructions in "Converting a Class-A Metal Chimney
to a Direct Vent System" section.
These units use the "balanced flue" technology
Co-Axial system. The inner liner vents products
of combustion to the outside while the outer pipe
draws outside combustion air into the combustion
chamber thereby eliminating the need to use heated
room air for combustion and losing warm room air
up the chimney.
Note: These flue pipes must not be
connected to any other appliance.
The gas appliance and vent system must be vented
directly to the outside of the building, and never
be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas
appliance must use its own separate vent system.
Common vent systems are prohibited.
IMPORTANT
Read all instructions carefully before starting the
installation. Failure to follow these instructions
may create a fire or other safety hazard, and will
void the warranty. Be sure to check the venting and
clearance to combustible requirements. Consult your
local building codes before beginning installation.
The location of the termination cap must conform
to the requirements in the "Exterior Vent Terminal
Locations" section.
Combustion and Ventilation Air
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra provision for combustion air inside the
room is not required.
Minimum ceiling height
is 36"/914mm from top
of unit.
Safety Screen
Installation
1.
Attach the safety screen by placing screen
over the glass door.
2. To remove, lift up slightly and pull away from
unit.