Regency
®
PG36 Gas Fireplace
|
17
installation
The PG36 is approved for a 37 ft. (11.3 m) straight vertical, with
Simpson Dura-
Vent Co Axial Flue GS
flue systems for Propane and NG, as per diagram 3.
The shaded area in diagram 3 shows all allowable combinations of straight
vertical and offset to vertical terminations with
Simpson Dura-Vent Co Axial
Flue GS
flue systems for Propane and NG. Maximum two 45
o
elbows allowed.
•
The vent restrictor must be used in the shaded area. Vent restrictors are
shown in images below.
•
Flue must be supported at offsets
• Firestops are required at each floor level and whenever passing through
a wall.
• Maintain clearances to combustibles as listed in the "Clearances," "Locating
Your Gas Fireplace," "Combustible Mantels," "Mantel Leg Clearances" &
"Framing and Finishing" sections.
Diagram 3
Vent Restrictor Installation
Check the vent diagrams to determine whether the vent restrictor is needed
for your vent configuration.
The vent restrictor is packaged with the manuals inside the firebox.
If restrictor is required:
1) Remove the top louver.
2) Open and remove the glass door front.
3) Remove the internal baffle (3 screws) at the top of the firebox.
4) Place the restrictor on the baffle plate (see diagram below) and re-install
the internal baffle plate.
5) Replace the door and louvers.
6) Fire up the unit and check for proper flame appearance and glow on logs.
The vent restrictor must
be used in the shaded
area only
Restrictor #2