10
|
Regency
®
PG36 Gas Fireplace
installation
Flueing Introduction
The PG36 uses the "balanced flue" technology
Co Axial system. The inner liner flues products of
combustion to the outside while the outer liner
draws outside combustion air into the combustion
chamber thereby eliminating the need to use heated
room air for combustion and losing warm room air
up the chimney.
Note:
These flue pipes must not be connected
to any other appliance.
The gas appliance and flue system must be flued
directly to the outside of the building, and never be
attached to a chimney serving a separate solid fuel
or gas burning appliance. Each Co Axial Flue gas
appliance must use it's own separate flue system.
Common flue systems are prohibited.
Before the unit is slid into position, install the
provided spacers to the side of the fireplace
as follows;
1. Align the screw locations on spacer with screw
locations on the side of the firebox and secure
in place using 3 screws.
2. Repeat for other side.
NOTE: The side nailing strips are to be in-
stalled to the spacer after the spacer
is attached to the unit.
Spacer
Left Side Shown
Premium Flush Front Spacer
Installation
Side
Nailing Strips
"C" Screw Position:
For a facing material depth of 32mm, the top facing
support must be reversed.
Unit Assembly Prior to
Installation
The Top Facing Support, the Side Nailing Strips and
the 2 Top Standoffs must be correctly positioned
and attached to the top before unit is slipped into
position.
Top Standoff Assembly
The top standoffs are shipped in a flat position and
must be folded into shape and attached.
1. Remove the standoffs from the fireplace top.
2. Take each standoff and bend into the correct
shape. Bend up at the bend lines until the screw
holes in the standoff and the pre-punched screw
holes on the fireplace top line up.
3. Attach the standoff securely to the top with 2
screws per standoff (on opposite corners).
Top Facing Support Side Nailing
Strips
Determine the total thickness of facing material
(e.g. plasterboard plus ceramic tiles) to allow the
finished surface to be flush with the front of the
unit. Total facing thickness can vary from 13mm
to 32mm thick.
The Top Facing Support can be mounted in 3
different positions depending on the thickness of
the facing material.
1. Mount Top Facing Support using the 3 supplied
screws into the three pre-punched screw holes
on the top front of the unit. Use hole positions A,
B, or C depending on your facing depth.
Side
Nailing Strips
2. Fold out the two nailing strips on each side.
Screw
Position
Facing Material
Depth
A
13mm
B
22mm
C
*
32mm
*
For "C" screw position the top facing support
is reversed.
Содержание Panorama PG36 Series
Страница 3: ...Regency PG36 Gas Fireplace 3 dimensions Unit Dimensions...
Страница 28: ...28 Regency PG36 Gas Fireplace installation Wiring Diagram...
Страница 47: ...Regency PG36 Gas Fireplace 47...