PG36 Gas Fireplace
|
13
installation
Horizontal or Vertical Terminations
Simpson Dura-vent Flueing
The Simpson Dura-Vent Co Axial Flue System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items
are offered in decorative black, as well as galvanized finish. We recommend using the galvanized finish for installation with the PG36.
The minimum components required for a basic
horizontal termination are:
1 Horizontal Termination Cap
1 90
o
Elbow
1 Flue Adaptor
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Flat Wall Installation
Wall Thickness
(mm)
Vent Length Required
(mm)
102mm - 140mm
152mm
178mm - 216mm
229mm
254mm- 38mm
305mm
229mm - 368mm
279 - 371mm Adj. Pipe
381mm - 597mm
432- 610mm Adj.Pipe
Corner Installation
Wall Thickness
(mm)
Vent Length Required
(mm)
83mm - 171mm
279 - 371mm Adj. Pipe
197mm - 413mm
432- 610mm Adj.Pipe
184mm - 222mm
152mm + 305mm
229mm + 229mm
108mm- 146mm
152mm + 305mm
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap. For
siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the flue terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
Rigid Pipe Adaptor
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Length
Adj.Pipe Length
90 Elbow
o
Horizontal
Termination
Cap
Wall Thimble
Vinyl Siding
Standoff (Optional)
Pipe
Not supplied by FPI