6
|
Regency
®
PG36 Gas Fireplace
installation
Installation Checklist
1. Locate appliance. Refer to the following sections:
a) Locating Your Gas Fireplace
b) Combustible Mantels
c) Mantel Leg Clearances
d) Framing and Finishing
e) Flueing
2. Assemble Top Standoffs and Top Facing Support
and Side Nailing Strips. Refer to the "Unit
Assembly Prior to Installation" section. (NOTE:
must be done before installing unit into fireplace.)
3. Install flue, refer to the "Horizontal Termination"
& "Vertical Termination" sections.
4. Make gas and electrical connections. Test the
pilot. Must be as per diagram. Refer to the " Pilot
Adjustment" section.
5. Install standard and optional features. Refer to
the following sections where applicable:
a. Log Set Installation
b. Flush Door
c. Premium Flush Front
d. Remote Controls
6. Final check.
Before leaving this unit with the customer, the installer
must ensure that the appliance is firing correctly and
operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 33 MJ/h) after
burning appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
Important Message
SAVE THESE INSTRUCTIONS
The PG36NG-6 or PG36LP-6 Room Sealed
Fireplace must be installed in accordance with AS/
NZS5601 and these instructions. Carefully read
all the instructions in this manual first. Consult the
"authority having jurisdiction" to determine the need
for a permit prior to starting the installation. It is the
responsibility of the installer to ensure this fireplace
is installed in compliance with manufacturer's
instructions and all applicable codes.
Before You Start
NOTE:
NOT INTENDED AS A FIREPLACE INSERT.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
INSTALLATION AND REPAIR SHOULD
BE DONE BY A AUTHORISED SERVICE
PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY AN AUTHORISED SERVICE
PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS OF
THE APPLIANCE BE KEPT CLEAN.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID YOUR
WARRANTY AND MAY CAUSE A SERIOUS
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY
THE FIREPLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING
IGNITION.
YO U N G C H I L D R E N S H O U L D B E
C A R E F U L LY S U P E RV I S E D W H E N
THEY ARE IN THE SAME AREA AS
THE APPLIANCE. TODDLERS, YOUNG
CHILDREN AND OTHERS MAY BE
S U S C E P T I B L E TO AC C I D E N TA L
C O N TAC T B U R N S . A P H Y S I C A L
BARRIERS IS RECOMMENDED IF
THERE ARE AT RISK INDIVIDUAL IN
THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS
OUT OF THE ROOM.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE. DO NOT
USE AEROSOLS IN THE VICINITY OF THIS
APPLIANCE.
General Safety Information
1. The appliance shall be installed in accordance
with the manufacturer's installation
instructions,local gas fitting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations, with
AS/NZS5601
2.
Installation and repair should be done ONLY
by an authorised person.
3.
THIS APPLIANCE IS NOT INTENDED AS A
FIREPLACE INSERT. DO NOT CONNECT TO
MASONRY FLUE.
4.
This appliance must be connected to the
specified flue and termination cap to the
outside of the building envelope. Never flue
to another room or inside a building. Make
sure that the flue is fitted as per Flueing
instructions.
5. Inspect the flueing system annually for blockage
and any signs of deterioration.
6. Flueing terminals shall not be recessed into a
wall or siding.
7. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
8. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
9. Wear gloves and safety glasses for protection
while doing required maintenance.
10. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
11. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
12. Installation and any repairs to this appliance
should be done by an authorised service
person. An authorised service person should be
called to inspect this appliance annually. Make
it a practice to have all of your gas appliances
checked annually.
13. Do not slam shut or strike the glass door.
14. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used
in this appliance.
15. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
This appliance will shut down during a
power supply interruption and/or if there
is insufficient voltage to the appliance.
"This unit must always terminate /flue
directly to the outdoors."