Regency Excalibur
®
P90-10 Zero Clearance Direct Vent Gas Fireplace
|
45
45
|
maintenance
4.
Connect fan ground cable to ground lug. Refer
to wiring diagram.
5.
Slide the thermodisc/cover assembly into the
bracket clip on the underside of the firebox.
Check that no wire will touch the hot surfaces.
Diagram 2.
6.
Install the Fan Control Module (FCM) on the base
of the unit to the left of the gas valve. Plug the
FCM into the outlet.
7.
Plug in the fan power cord to the Fan Control
Module into the outlet marked “Fan”. Plug the
FCM-COM wire from the remote control wiring
harness into the location on the Fan Control
Module marked “COM”. Turn the switch on the
Fan Control Module to the ON position. ON is to
the left. The “O” is the off position.
Diagram 1
Diagram 3
Diagram 2
8.
Secure the fan wires and power cord by attaching
one of the adhesive backed wire holder clips.
onto the stove base. Use the second clip to
bundle up the wires approximately 4" from the
control box. Ensure that there is no interference
with the wires when the louver is closed and
that no wire will touch the hot metal surfaces
or sharp edges.
9.
Plug the fan power cord into the rear end of
the receptacle box to provide the maximum
clearance from the louvers.
To Remove the Fan
1.
Shut the power off.
2.
Reverse the above instructions.
Note: The bearings are lubricated for life. Do
not lubricate them. Make sure you vacuum
the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.
FAN MAINTENANCE
120 Volt AC power is needed for the fan. The fan
can be hard wired if desired. The outlet should be
installed in the receptacle box on the left hand side
by a qualified electrician. The neutral (wider) slot of
the polarized outlet should be at the top.
Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.To Install the Fan
1.
Shut the power off.
2.
Remove the bottom louver door.
3.
Slide the fan in towards the rear of the unit and
slip it over the two mounting studs. Take care
not to damage the insulation on the fan base.
Ensure that the fan blades do not rub against
the valve tubing.
Diagram 1.
IMPORTANT:
THESE FANS COLLECT A LOT OF
DUST FROM WITHIN YOUR HOME.
ENSURE YOU MAINTAIN THESE FAN
MOTORS ON A REGULAR BASIS BY
VACUUMING THE FAN BLADES AND
THE HOUSING WITH A SOFT BRUSH
NOZZLE.