14
|
Regency Excalibur
®
P90-10 Zero Clearance Direct Vent Gas Fireplace
|
14
installation
1
02.12.15
919-508
P90
1. Fold out side nailing strips from the side of the unit to 90º as shown
below.
Determine the overall combined thickness of the non-combustible board
+ finished material being used. The nailing strips can be adjusted up to
3-3/8".
OPTIONAL FRAMING KIT
An optional framing kit is available to facilitate easier installation of the noncombustible board.
The optional framing kit is to be installed within the existing wood framing. The framed opening is 46-1/2" wide x 45-1/4" high or 46-3/8" high if using the base stand-
offs and 21-1/2" deep. See instruction manual for complete details.
2. Adjust the nailing strips by loosening 2 screws on each nailing strip -
adjust and retighten screws.
3. Attach both vertical studs and secure using pointed wood screws to pen-
etrate steel studs to secure. There are 6 screws which are not provided.
(2 at bottom, 2 at top and 2 on sides). (Corner framing shown in diagram).
NOTE: Ensure the flat side of the steel stud is facing the wood framing.
4. Slide the unit into position. Hook up gas, venting and electrical prior to
installing the remaining steel studs.
5. Secure the top horizontal steel stud as shown with 2 screws per side.
6. Secure the wide horizontal stud with with 2 screws per side..
7. Secure 2 thin vertical studs on either side of the appliance with 4 screws
each. Above screws are provided.
Horizontal stud -
see Step 5
Wide Horizontal
stud - see Step 6
Fold out nailing strips to 90º
Adjust nailing strips
Thin Vertical
studs - see Step 7
Framing kit dimensions
Attach tall vertical studs from
framing kit to existing wood
framing.