Regency Excalibur
®
P90-10 Zero Clearance Direct Vent Gas Fireplace
|
35
35
|
installation
LOG SET INSTALLATION
01/04/08
918-067c
P36D / P90
Page 1 of 4
Notch
Bracket
Bracket
02-51
02-75
02-51
3)
Place the Log 02-75 on the rear log support pins with the
fl at side to the back.
LOG SET INSTALLATION
1)
Carefully remove the logs from the box and unwrap them.
The logs are fragile, handle with care -
do not force into
position.
The "02" reference numbers (i.e. 02-75) are
molded into the rear of each log.
02-75
Notch
Read the instructions below carefully and refer to the
diagrams. If logs are broken do not use the unit until
they are replaced. Broken logs can interfere with the
pilot operation.
The gas log kit (Part #780-930) contains the following
pieces:
a) 02-75
Rear Log
b) 02-55
Middle Left Log
c) 02-50
Front Left Log
d) 02-53
Center Left Log
e) 02-51
Front Bottom Log
f) 02-54
Center Right Log
g) 02-52
Middle Right Log
h) 902-156 Embers
i) 902-179 Vermiculite
j) 946-669 Platinum Embers
(supplied with packaged manual)
NOTE: If you will be installing the optional Brick Panels
(P36D & P90 only), install the Brick Panels prior
to installing the logs.
Model shown has P36D and P90 burner/grate with
brick panel option.
4)
Place Log 02-51 on the front right side of the burner. Push
the back of the log against the 2 brackets with the notch
on the bottom right side of the log fi tting into the right side
of the grate.
2)
Sprinkle the vermiculite over base brick panel.
02-75
02-51
02-53
02-54
02-55
02-52