18
TEST RESULTS REPORTING
Fig. 9 (next page) illustrates a typical device-generated report for
the ANSI A326.3 Standard Test Method (field/dry, sheet one of
three only). The report lists the four required measurements (per
the test method.) The photos are often helpful for positive
identification of particular test areas (e.g. in front of a doorway or
staircase). Each graph represents one measurement of the set.
Graphs can be useful in determining the degree of surface
variation for a given area. The average DCOF value for each
measurement is the recorded result. The median of the four
averages is the final test result. Single SCOF or DCOF tests will
display one measurement per report. Other test method reports
may be formatted differently than the illustrated example. Test
report folders are created first by the device serial number, the
test date, and then the area ID. The pdf files are arranged by
Date/AID/LID/test sequence. The DATA.LOG test data files are
stored in a folder created under the test date/area ID. These data
files may be renamed to DATA.TXT or DATA.CSV for importing
into various spreadsheet programs.