Table 37
:
Troubleshooting - Event Log Messages
Log Message
Description
WARNING: Clock Offset
Close to End of Scale
The reference clock calibration procedure initiated by
the user has been completed, but the clock offset is at
the boundaries of the base station’s capabilities
WARNING: DL aggregated
Guaranteed Rate exceeds
Capacity
The aggregate guaranteed minimum rates configured
for service flows using RTPS and UGS scheduling
exceeds the downlink capacity of the sector.
WARNING: Indoor Unit
Temperature > [c] Celsius
The base station indoor unit has exceed recommended
operating temperatures.
WARNING: ODU
Temperature is [c] Celsius
The operating temperature of the base station ODU is
nearing the limit of its operating temperature. No action
is taken.
WARNING: Power Supply
[X] is Off
Where X is either A or B. This signifies that the relevant
power supply has been detected, but it is not supplying
power to the base station.
WARNING: UL aggregated
Guaranteed Rate exceeds
Capacity
The aggregate guaranteed minimum rates configured
for service flows using RTPS and UGS scheduling
exceeds the uplink capacity of the sector.
WRONG CRC over I2C
The stored interface configuration data has failed
integrity check.