Troubleshooting - Event Log Messages
Log Message
Description
Long Reset
The base station has been reset to factory defaults by
the user.
Master Detected
A slave has detected the presence of a master.
Master Function Activated
This base station is configured as Master, and it has
successfully activated.
Master is Not Detected
A slave has failed to detect the clock signal of a master
Master or GPS must be
connected. Waiting...
A backup slave has not detected the presence of a
Master or GPS clock source. It will wait for one before
activating its RF interface.
Master with GPS Function
Activated
This base station is configured as Master, and has been
successfully activated.
NOTICE: Watchdog is
Disabled
A jumper installed during factory burn-in was not
properly removed before shipping.
Ntp client: Invalid address
The IP address of SNTP server cannot be resolved
Ntp client: Server Unsync
The received timestamp is 0, or the SNTP server
suggests it is not synchronized
Ntp client: Timeout
The SNTP server does not reply to SNTP requests
Ntp client: Version
unsupported
SNTP server version number is greater than 3
Other Backup Detected.
Waiting...
This base station is configured as a Backup Slave, but
another backup slave has been detected.
Other Master Detected.
Waiting...
The base station is configured to act as a Master, but it
has detected the presence of another Master.
P1 Watchdog Reset
The P1 processor has encountered an exception, and
has prompted a reboot of the base station
P2 Watchdog Reset
The P2 processor has encountered an exception, and
has prompted a reboot of the base station
P2-Task: %#x \"%s\
This message is displayed only after a watchdog reset
occurs. It provides information about the software
exception that caused the watchdog.
Parameters are reset to
factory defaults
This message appears after the user has initiated a
long-reset to factory defaults
Power Supply [X] is On
Where X is either A or B. This signifies that the relevant
power supply has been detected and is properly
supplying power to the base station
Radio Type [XX]:
TBXXXXFX
This message is simply a confirmation of the type of
radio connected to the IDU. It should match with the
radio type printed on the ODU’s sticker.
RedMax base station Ver.
X.X.X started
System startup message.
Reference Clock
Calibration Done
The reference clock calibration procedure initiated by
the user has been completed.
Reference Clock
Calibration Failed
The reference clock calibration procedure initiated by
the user has failed.