Reset Switch
The
Reset
button is recessed in the front panel of the terminal. To operate the switch,
use a small narrow object (i.e., paper clip) to depress the switch.
Table 13
:
System - Front Panel Reset Switch
Operation
Result
Depress switch
less than 5
seconds
Short-reset. A short-reset is equivalent to cycling the
terminal power off/on. Statistics counters are reset.
Depress switch
longer than 5
seconds
Long-reset. A long-reset sets the IP address and
password to the factory defaults. Refer to Troubleshooting
section.
3.1.6 Grounding
Connection
A ground terminal is located on the rear of the terminal. Correct grounding is very
important for safe operation of wireless equipment.
3.1.7 Console
Port
The console port requires a crossover (null modem) cable to connect directly to a PC
serial port emulating a VT-52 or VT-100 terminal. The following table lists the default
settings for the Console port:
Table 14
:
System - Console Port Default Settings
Baud 57,600
Data Bits
8
Flow Control
None
Parity None
Stop Bits
1
The following table lists the Console port pinout and associated signals.
Table 15
:
System - Console Port (RS-232) Pinout
Pin
Name
RS232
V.24
Description
2 RXD
BB
104
Receive
Data
3 TXD
BA
103
Transmit
Data
5
GND
AB
102
System Ground
Note: V.24 column is ITU-TSS V.24 circuit name.