DGL1010VS OPERATING INSTRUCTIONS
Setting Slope/Grades
(refer to diagram page 9)
The DGL1010VS can digital dial in a grade as a percentage to three decimal
places. In Slope (Grade) Mode you can set a Grade in either the X or the Y
Axis of up to 10.000% see the markings on top of laser for axis alignment.
In Slope (Grade) mode the “TILT” and “V-W-S” features can still be used.
The DGL1010VS is dual grade, so a grade can be set on the X and Y axis
simultaneously. Slope (Grade) can be set from either the laser’s keypad or
the remote and the grade being selected is shown on both LCD displays.
Using the scope and axis adjustment plate aids accurate alignment of axis.
•
Turn the laser on, allow to level and begin rotating.
•
To select a grade on the “X” axis (see markings on top casing) press
and hold 2 seconds the “X/Y” button on the keypad/Remote. The
“X” and “+” will flash on the LCD screens a grade can now be set on
the “X” axis.
•
To select a negative grade i.e slope up in the direction of the “-X” (on
casing) press the down arrow button . To change back to a positive
slope press the up arrow button .
•
Next press (short press) the “X/Y” button to shift the active digit one
place to the right. Use the up arrow to increase the percentage
required and use the down arrow to reduce it. For example we
want to set a 1.666% slope so leave this first digit to “0”. (This first
digit is only if you want to set the maximum possible percentage grade
of 10.000% in that situation you would set the digit to “1”)
•
Press (short press) the “X/Y” button to shift the active digit another
place to the right and use the up and down arrows to select the required
number, in this example “1”. Then repeat the operation again press
“X/Y” button and arrows to select the next three digits to “6” until we
get the 01.666% in our example.
•
Next long press (2 seconds) the “X/Y” button this makes the “Y”
axis active (flash) and a grade can be set in the same manner the “X”
Axis was set or if no second grade is required leave all digits as “0”. To
seal in these grades and to tell the laser to set them another long press
of the “X/Y” button is required or no not enter anything for 8 seconds,
The laser will beep and after a few seconds of setting the grades the
laser will rotate with the desired grade/grades. The laser will take
longer to set larger and dual grades.