background image

CONTENTS

User 

Safety 

     2

Introduction and DGL1010VS Accessories 

 

 

3

DGL1010VS 

Diagram     4

Operating 

Instructions 

    6

 Batteries 

    6

 Power 

and 

Tilt 

Mode 

   7

 Grade 

Setting 

   8

 Vertical 

Rotation 

Mode 

   11

 Laser 

Receiver 

LR715/LR720 

  13

Calibration Self Check & Technical Specifications   

 

15

Warranty 

      16

User Safety

• 

Laser output sign lies near the output aperture.

• 

Do not stare directly into laser beam.

• 

Do not disassemble the instrument or attempt to  

 

perform any internal servicing. Repairs and service 

 

should be performed only authorised service  

 

centres of Redback Lasers. 

• 

This instrument complies with the safety

 

Classification standards of laser radiation.

2

CAUTION: Class 3r laser <5mW at 635nm.

Do NOT stare into laser beam or aim at 

another person.

Follow relevant Australian Standards

Copyright © CMI LasersTM RedBack lasersTM and Level1LasersTM . All rights reserved CMI Industries Pty Ltd 2014

No artwork or photographs produced by CMI Industries Pty Ltd may be used copied or reproduced without the written consent 

from CMI Industries Pty Ltd

Содержание DGL1010VS

Страница 1: ......

Страница 2: ...t or attempt to perform any internal servicing Repairs and service should be performed only authorised service centres of Redback Lasers This instrument complies with the safety Classification standar...

Страница 3: ...levels and re sets the grade if required The DGL1010VS also features a smart long range remote control complete with an LCD display duplicating the display on the laser level itself This make setting...

Страница 4: ...ope Mount 3 Rotating Head 4 Heavy Rubberised Casing 5 Keypad 6 LCD Display Keypad 5 4 Power On Off laser level Setting Grade Tilt On Off Manual Mode 6 Setting Grade Axis Remote Channel Select Re Level...

Страница 5: ...Off Reception Sensors Rubber Casing LCD Display Repeated on rear Bubble Vial top and side Control Panel Ruberised Casing Setting Grade Axis Setting Grade Manual Mode Vibration Wind Setting Remote Chan...

Страница 6: ...f the remotes batteries Handy Hints Prior to initial use charge the rechargeable batteries for at least 8 hours Running rechargeable batteries completely flat will increase battery life The DGL1010VS...

Страница 7: ...urn on again Tilt Mode Tilt mode is somewhat similar to tilt on a pinball table in that if when running the DGL1010VS detects significant disturbance or movement that could alter the accuracy of your...

Страница 8: ...slope press the up arrow button Next press short press the X Y button to shift the active digit one place to the right Use the up arrow to increase the percentage required and use the down arrow to re...

Страница 9: ...s NOTE In grade mode if nothing is entered for 8 seconds whatever has already been entered will be set and the laser will grade and rotate If you have not entered all the numbers then re enter grade m...

Страница 10: ...rations may cause the laser to pause rotation like this so regularly that it slows your work down The V W S button is a vibration wind sensor activating this will desensitise the laser to these vibrat...

Страница 11: ...ed the same as when in normal horizontal rotation mode Once levelled and rotating you can electronically aim the dot laser to a target left to right by pressing and holding the grade slope arrow butto...

Страница 12: ...isticated radio frequency remote control with full LCD display that provides real time information to and from the laser Radio frequency means that you have you an exceptional range of up to 50m it al...

Страница 13: ...re showing off level these two coarser modes are more suitable for general site levelling The Back Light button toggles the LCD display back light The LR715 has two large LCD displays with progressive...

Страница 14: ...the laser beam being emitted by your rotating laser level To select sound option press the Sound button long press which will cycle through off low high default sound levels To select Accuracy press t...

Страница 15: ...n Australia prior to despatch and should under normal conditions not go out of calibration A calibration certified sticker with the date and name of technician is located on the laser itself It is wor...

Страница 16: ...nts that our products will be free from defects in material and workmanship for the warranty period CMI promises to repair or replace free of charge the product or part of product if found to be fault...