17
2 INSTALLATION
GUIDE
1 2 3 4 5
1 2 3 4 5
Blown Fuse Indicators
Master Override switch
1 2 3 4 5
1 2 3 4 5
15
20
20
15
Master Override Indicator
10A max circuit
override switches
30A max circuit
override switches
Note: Fuse values may vary from those shown in this diagram, depending on individual system requirements
2.5.3 Blown Fuse Indicators
A blown fuse is indicated by an illuminated indicator (white) above the blown fuse.
Investigate and rectify the cause of the failure before replacing with an appropriately
sized fuse. The blown fuse will also be indicated by the icon on the display turning RED.
2.5.4 Override Switches
Under normal conditions each load output channel may be switched using the display,
however should a load need to be manually switched on, the override switches (located
between the two fuse banks) may be used.
Overriding is a two stage process - fi rstly override mode must be enabled using
the master override switch (located to the left of the two switch banks). The master
override indicator (red) will illuminate to denote that override mode is enabled.
Once enabled, the individual load channels may be operated using the relevant
switches. During override the system cannot be controlled by the display.
Ensure that the channel and master override switches are turned off after use to prevent
accidental operation of the channel and/or fl attening of either the Starter or Auxiliary
battery.