SYNC TRIGGER BUTTON CIRCUIT
The SYNC connector has a 3.3 V Schmitt trigger (5 V tolerant). The trigger is not a switch closure circuit, so it requires
that the trigger source supplies current. Both edges of the input signal may be used as a trigger.
NOTE:
The SYNC trigger button circuit only applies to the DSMC2 Base Expander.
For example, this is the behavior of the circuit when the GPI trigger is used for record start/stop:
Start Record
: On ground to 3.3 V transition
During Record
: Hold at 3.3 V
Stop Record
: On 3.3 V to ground transition
During Stop
: Hold at ground
Figure: Trigger Button Circuit Diagram
NOTE:
In the diagram above, values are approximate. Use standard values.
COMPATIBLE CABLES
790-0154
: 3BNC-to-00 LEMO Sync Cable
790-0187
: 4-Pin 00 LEMO-to-Flying Lead
790-0415
: RED Start/Stop Cable (14-Pin LEMO to SYNC, CTRL, BNC)
790-0428
: RED Start/Stop Cable (14-Pin to 00B SYNC)
C O PYR I G HT © 2 0 1 7 R ED.C O M , I NC
9 5 5 - 0 1 2 7 _V 6 .3 , R EV - M
|
2 0 2
RED RAVEN OPERATION GUIDE
Содержание RED DRAGON 4.5K
Страница 1: ...RED RAVEN RED DRAGON 4 5K V6 3 RED COM RED RAVEN OPERATION GUIDE...
Страница 187: ...FRONT VIEW Figure RAVEN Front View COPYRIGHT 2017 RED COM INC 955 0127_V6 3 REV M 187 RED RAVEN OPERATION GUIDE...
Страница 188: ...BACK VIEW Figure RAVEN Back View COPYRIGHT 2017 RED COM INC 955 0127_V6 3 REV M 188 RED RAVEN OPERATION GUIDE...
Страница 190: ...SIDE VIEW LEFT Figure RAVEN Side View Left COPYRIGHT 2017 RED COM INC 955 0127_V6 3 REV M 190 RED RAVEN OPERATION GUIDE...
Страница 191: ...TOP VIEW Figure RAVEN Top View COPYRIGHT 2017 RED COM INC 955 0127_V6 3 REV M 191 RED RAVEN OPERATION GUIDE...
Страница 192: ...BOTTOM VIEW Figure RAVEN Bottom View COPYRIGHT 2017 RED COM INC 955 0127_V6 3 REV M 192 RED RAVEN OPERATION GUIDE...