76
Page
Connect the fan power
cable from the appliance
to the termination.
Ensure the cable is
clamped only to the intake
pipe to secure the cable
from hanging loose &
touching the hot flue gases
pipe.
Use the clamp provided.
The clamp can be opened
like a collar and fitted
around on the flue.
Flex collar and fit around the access panel. Socket the
collar all the way up close to the air intake slots Ensure
there is a rubber seal top and bottom of the collar.
Use only the screws provided to tightly fit the collar to seal
the access panel.
Insulation must start as close to the gas space heater as
possible
(Only exhaust flue is to be insulated)
Insulation to be fully closed
and sealed along length.
Fit flue exhaust insulation
Insulated with 25mm foil
faces glasswool pipe
insulation within 0.3m
of each end of flue, as
supplied by Glen Dimplex
Australia.
Bends were practical
should be insulated, by
cutting the insulation into
segments and taping
together.
Joins can be taped
together using aluminum
foil self adhesive tape.
Insulation must be fitted
prior and after the inline
powerflue fan.
Failure to fit insulation on the exhaust flue may result in
condensation failures with the appliance.
Содержание Element 1200 MARK 2
Страница 6: ...6 Page OPERATION INSTRUCTIONS ...
Страница 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Страница 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Страница 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Страница 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Страница 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Страница 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Страница 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Страница 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Страница 81: ...81 Page ...
Страница 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Страница 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Страница 102: ...102 Page ...
Страница 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...
Страница 123: ...123 Page APP EN DIX 1 FL UE TERMINATION ...