E X T E R N A L WA L L M O U N T E D F A N M O D U L E I N S TA L L AT I O N
1. Wall mounted fan module – terminal must be installed
with clearances as specified by AS5601.1 Clause
6.9.3.
2. Run exhaust flue and air intake flue as required
Maximum run 5m. Flues can be run next to each
other. Maintain clearances to combustibles.
3. Connection to appliance
4. Repeat above with air intake flue pipe to heater
connection.
5. Clip flues as required to provide adequate support.
6. Connection to wall mounted fan terminal.
Cut tube to length where
required.
Ensure ends are burr free
and round, test fit flue will
slide over connection.
Apply an 8mm silicon
bead fully around the
inside of the flue end
(heater connection end)
Fit flue clamp over flue
(loosely).
Recommended Silicon
– Non-acetic, neutral
cure 150°C or higher
temperature rated.
Bostik RTV 926 or similar.
Apply an 8mm thick silicon
bead fully around heater
connection approx. 10mm
from the top.
Slide flue onto connection
spigot fully.
Tighten clamp fully.
Wipe excess silicon,
visually check connection
to ensure connection is
fully sealed
Remove cover from fan
terminal
Remove main assembly
from the rear wall
mounting plate assembly.
Remove the 5 screws as
shown. (Do not remove
fan plate screws)
Lift off main fan terminal
assembly.
325
80
125
120
382
12
8
12
0
31
0
280
Содержание Element 1200 MARK 2
Страница 6: ...6 Page OPERATION INSTRUCTIONS ...
Страница 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Страница 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Страница 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Страница 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Страница 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Страница 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Страница 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Страница 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Страница 81: ...81 Page ...
Страница 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Страница 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Страница 102: ...102 Page ...
Страница 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...
Страница 123: ...123 Page APP EN DIX 1 FL UE TERMINATION ...