Connection to wall terminal
Loose fit connections (wall termination connections)
Locate terminal on wall and predrill mounting holes where
required.
Cut flue exhaust tube (hot tube) to length (Flue must
extend a minimum of 50mm past the exit face of wall.) It
is recommended that the tubes are cut slightly longer and
pushed back into wall upon fixing of wall terminal. Allow
flue movement between terminal and last flue hanging
clip.
Cut Air intake as per flue exhaust.
Ensure ends are burr free and round, test fit flue will slide
inside both the hot exhaust connection and air intake
connection.
Feed hot exhaust flue
into connection, ensure
inserted 50mm. Fit retaining
screw from below.
Feed air intake flue
into connection, ensure
inserted 50mm. Fit retaining
screw from below.
Insulation must start as close to the gas space heater as
possible
(Only exhaust flue is to be insulated)
Insulation to be fully closed
and sealed along length.
Fit flue exhaust insulation
Insulated with 25mm foil
faces glasswool pipe
insulation within 0.3m
of each end of flue, as
supplied by Glen Dimplex
Australia.
Содержание Element 1200 MARK 2
Страница 6: ...6 Page OPERATION INSTRUCTIONS ...
Страница 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Страница 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Страница 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Страница 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Страница 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Страница 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Страница 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Страница 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Страница 81: ...81 Page ...
Страница 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Страница 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Страница 102: ...102 Page ...
Страница 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...
Страница 123: ...123 Page APP EN DIX 1 FL UE TERMINATION ...