43
Page
Setup with internal fan module with roof top
termination – mid flue mounted
Maximum 5m flue length
Note- fan module can be appliance mounted or mid
mounted when finishing with the rooftop termination.
Roof top termination
1. Rooftop termination must be installed with clearances
as specified by AS5601.1-2013.
2. Run exhaust flue and air intake flue as required –
Maximum total run 5m per flue. Flues can be run next
to each other. Maintain clearances to combustibles.
3. Mount fan controller in the required location. (Access
to the fan module is required for servicing, if the fan
module is located inside a boxed frame, allow a 450
x 450 access panel).
Run flue from appliance
to bottom entry on fan
module.
Support flue with brackets
as required
Cut flue to length to suit
connection.
Ensure ends are burr free
and round, test fit flue will
fit over connection.
Apply an 8mm silicon
bead fully around the
inside of the flue end
(heater connection end)
Fit flue clamp over flue
(loosely).
Apply an 8mm thick silicon
bead fully around heater
connection approx. 10mm
from the top.
Slide flue onto connection
spigot fully.
Tighten clamp fully.
Wipe excess silicon,
visually check connection
to ensure connection is
fully sealed
Содержание Element 1200 MARK 2
Страница 6: ...6 Page OPERATION INSTRUCTIONS ...
Страница 20: ...20 Page IN STALL ATION INSTRUCTIONS ...
Страница 26: ...26 Page 0 5M FLUE CONFIGURATION ...
Страница 30: ...30 Page Flue runs 0m to 5m length rooftop termination with external motor ...
Страница 34: ...34 Page 0M 5M FLUE INTERNAL FAN AND WALL TERMINATION INSTALL ATION ...
Страница 42: ...42 Page INTERNAL FAN ROOF TERMINATION ...
Страница 46: ...46 Page ROOFTOP TERMINATION WITH EXTERNAL MOTOR ...
Страница 49: ...49 Page 5 10M INSUL ATED FLUE CONFIGURATION ...
Страница 77: ...77 Page 10 13 5M POLYPROPYLENE FLUE CONFIGURATION ...
Страница 81: ...81 Page ...
Страница 89: ...89 Page Connect power cable connector Fit cable clamp to cable Fit front cover ...
Страница 98: ...98 Page 10 13 5M ROOFTOP POLYPROPYLENE FLUE CONFIGURATION ...
Страница 102: ...102 Page ...
Страница 103: ...103 Page SET UP WITH IN LINE OR APPLIANCE MOUNTED FAN ...
Страница 123: ...123 Page APP EN DIX 1 FL UE TERMINATION ...