EN
7
1.6 WIRING
Lift the transparent cover, unscrew the two side screw and remove the cover.
There are a PTR10 connector, seven FASTON, six grouping and one separated for grounding, a magnetothermic
switch with output prewired to the unit and one prewired protection fuse for the electric resistor.
PTR 10 terminal block
•
R1: N° 2 dry contact NA 6A 250V cosphy=1; driver for heat pump
•
R2: N° 2 dry contact NA 6A 250V cosphy=1; driver for recirculation pump.It is advisable to use a low voltage
buffer relè . Refer to wiring diagrams for details.
•
ALARM: N° 2 contacts for alarm / defrost signal from heat pump ( 230 Vac input)
•
NTC1: N° 2 contacts for NTC probe from storage tank.
•
NTC2: N° 2 contacts for NTC probe from return water line (optional, only for recirculation management)
FASTON description
•
Faston
(Power supply) Prewired to magnetothermic switch output.
•
Faston
(Protection fuse for electric resistor) Prewired to on-board fuse.
•
Faston
(Resistenza Elettrica) Electrical connection to the electric resistor of the storage tank.
•
Faston T Grounding.