1.3 ADDITIONAL REQUIRED MATERIAL (NOT SUPPLIED)
•
N° 1 Low voltage RELE (Recirculation pump buffer)
•
Wiring: use insulated copper wires of type,section and lenght indicated in
1.6
•
Cable Press
1.4 ELECTRICAL REQUIREMENT
•
Before the installation, be sure that the voltage of power supply is the same as the one indicated on the
device
•
All the electrical wiring must follow the local electrical codes.For details, call the dealer or an electrician.
•
All the electrical wiring must be done by a specialized electrician.
1.5 INSTALLATION
It is recommended that the system be installed by a qualified tecnician, following the attached instructions
Positioning
•
Make the holes for the electrical cables on the bottom of the box, following the existing tracks.
•
Use a cable gland of the appropriate size for each hole.
•
Fix the unit at the wall at maximum 2 m from the storage tank.
•
Make the wiring of the NTC probes so as to have shorter connections possible.
Tip:
Make three holes in witch to carry:
1.
Power supply 230 Vac
2.
NTC relè output (R1, R2)
3.
ALARM wire (from Acqua Unit) + electrical resistor driver cable