background image

APOLLO FYM - SPREADER CONTROLLER

2

Electromagnetic Compatibility (EMC)

This  product  complies  with  Council  Directive  2004/108/EEC
when  installed  and  used  in  accordance  with  the  relevant
instructions.

IMPORTANT, READ THIS BEFORE USING THE PS8000i

The

PS8000i

installation  is  a  part  of  the  Precision  Farming

System ("the System"). It is very important that you follow the
described  calibration  procedures  before  operating  the

PS8000i

instrument.  Calibration and operation of the

PS8000i

must  be  in  accordance  with  these instructions.  Use  of  the
System is subject to the following disclaimer;

1. So far as is legally permissible RDS Technology ("RDS"), or its

distributors,  shall  not  be  liable,  whatever  the  cause,  for  any

increased  costs,  loss  of  profits,  business,  contracts,  income,
or  anticipate  savings  or  for  any  special,  indirect  or
inconsequential  damage  whatsover  (death  or  personal  injury
excluded).

2. The  capabilities  and  functions  of  the  Precision  Farming

System  ("the  System")  are  limited  as  set  out  in  the
specification  of  the  System,  details  of  which are  contained in
the  Help  files  and product  literature  and  which  must  be  read
before using the System.

3. Without  prejudice  to  the  generality  of  the  above  it  is  hereby

acknowledged  that  the  System  is  not  designed  nor  intended

to a) originate variable treatment plans or b) achieve or avoid
any  application  rate  outside application  parameters,  which  in
both cases shall be the responsibility of the operator.

4. The standard terms and conditions of RDS (except clause 7),

a  copy  of  which  is  available  on  request,  apply  to  the  supply
and operation of this System.

Service and Technical Support

PLEASE CONTACT YOUR NEAREST RDS DISTRIBUTOR If
unknown then contact RDS Technology Ltd for further

information,
Tel :

+44 (0) 1453 733300

Fax :

+44 (0) 1453 733311

e-mail :

[email protected]

web :

www.rdstec.com

Our policy is one of continuous improvement and the
information in this document is subject to change without
notice. Check that the software reference matches that
displayed by the instrument.

© Copyright RDS Technology Ltd 2013

\UK746110.DOC

Содержание Apollo FYM

Страница 1: ...1 Apollo FYM Spreader Controller Calibration RDS Part No Document Issue Software Issue S DC 500 10 746 1 1 20 2 14 PS605 001rev09...

Страница 2: ...sion Farming System the System are limited as set out in the specification of the System details of which are contained in the Help files and product literature and which must be read before using the...

Страница 3: ...e Smoothing 8 2 1 4 Off Target Alarm 8 2 1 5 Info Weight 8 2 2 Loadcell Correction 9 Correction Span 9 Min Stat Weight 9 Dynamic Time 9 Dynamic Weight 9 Start Delay 9 Steady Weight 9 H Land Delay 9 T...

Страница 4: ...dth 14 5 1 1 Set current Working Width 14 5 2 Forward Speed Sensor 14 5 2 1 Select Sensor Option 14 5 2 2 Wheel sensor calibration Autocal 14 5 2 3 Wheel sensor calibration manually calculating the Fo...

Страница 5: ...y Alpha numeric values are entered via the right hand keypad You must press the key from 2 to 5 times to select the required letter Some keys have additional special characters not shown on the key le...

Страница 6: ...he contrast setting is adjusted so that the screen graphics can no longer be viewed i e completely light or dark don t panic you can navigate directly to the DISPLAY screen by pressing and holding the...

Страница 7: ...press 1 5 Select Control Software There are two lines displayed If the head unit does not have a secondary software module fitted both lines will be the same and switching between them has no effect I...

Страница 8: ...it is acceptable for the instrument to display a steady readout of 10 tonnes ha between those limits i e 3 In this case the rate lock on figure should be set to 3 0 Adjustable from 0 to 50 Default 2...

Страница 9: ...tem will resume DYNAMIC corrections This is to give the floor time to get to speed T Factor Delay This is the pause time after each new DYNAMIC correction has been made before the new correction start...

Страница 10: ...nu function immediately sends the data to the serial port The message Printing Data is displayed while data transfer is occurring If the bar on the screen stops filling up part way the instrument cann...

Страница 11: ...speed If necessary measure this speed using a hand held tachometer Note the speed displayed on the INFO screen The correct Cal factor Initial Factor x Displayed Speed Actual Speed Default 1 pulse per...

Страница 12: ...get rate then the response setting may be too high Default 100 Range 0 9999 3 4 3 Deadband The Deadband function sets the range over which the flow rate will vary about the target rate before the cont...

Страница 13: ...Rate This is the target application rate that is programmed on the MAIN screen Default 20 Range 0 9999 4 1 3 T Factor The T factor is the calibration factor that is altered while the spreader is disp...

Страница 14: ...the forward speed sensor This could be calculated based on the nominal tyre diameter or rolling distance and then entered manually ref section 1 1 3 however this does not take into account wheel slip...

Страница 15: ...for exactly 10 revolutions of the sensed wheel Measure this distance in inches or metres and divide by 20 to find the Speed Sensor Factor iii If 4 wheel magnets are installed the distance is 1 4 the...

Страница 16: ...e ALARMS SETUP button at the base of the screen 6 1 1 Low High RPM Alarm From the RPM SETUP screen you can also set a minimum and maximum RPM at which an alarm is triggered Set as necessary Default 0...

Страница 17: ...APOLLO FYM SPREADER CONTROLLER 17 Issue 1 12 12 13 Original Issue Issue 1 1 20 2 14 Ref CRQ5468...

Отзывы: