1

User Options

Configure basic instrument options.

1.1

Set Time and Date

If  you  need to  change  the  time  or  date  setting, position  the  cursor  against  the  relevant  line, key-in  the new

value and press                       .

1.2

Adjust Screen Contrast and Brightness

Figure 19

The screen may go darker at very high or very low temperatures. For example, on a very cold morning it may

take a short period of time for the display to gain normal contrast as the instrument warms up. This is a normal

characteristic of this type of display and does not mean the display is faulty.
If  by  accident  the  contrast  setting  is  adjusted  so  that  the  screen  graphics  can  no  longer  be  viewed  (i.e.

completely  light  or  dark),  don't  panic! - you  can  navigate  directly  to  the  "DISPLAY"  screen  by  pressing  and

holding the        key for at least 10 seconds. The instrument will bleep at 2-second intervals as long as the key

is depressed. You can then adjust the display using the arrow keys.

1.3

Customise

Information can be displayed in Metric or Imperial units by selecting the desired option via the SETUP menu.

Function

Units

Metric

UK Imperial

Forward Speed

km/hr

miles/h

Application rate

lg/ha

tonnes/ha

lbs/acre

tons/acre

Part/Total Area

hectares

acres

Tank volume/  Part/Total

volume applied

Tones

lbs

1.

Time/Date

4.

User Options

2.

Contrast

Brightness

UK572-16.PCX

3.

Customise

4.

User Options

4.

User Options

UK572-16.PCX

Содержание Apollo FYM

Страница 1: ...1 Apollo FYM Spreader Controller Calibration RDS Part No Document Issue Software Issue S DC 500 10 746 1 1 20 2 14 PS605 001rev09...

Страница 2: ...sion Farming System the System are limited as set out in the specification of the System details of which are contained in the Help files and product literature and which must be read before using the...

Страница 3: ...e Smoothing 8 2 1 4 Off Target Alarm 8 2 1 5 Info Weight 8 2 2 Loadcell Correction 9 Correction Span 9 Min Stat Weight 9 Dynamic Time 9 Dynamic Weight 9 Start Delay 9 Steady Weight 9 H Land Delay 9 T...

Страница 4: ...dth 14 5 1 1 Set current Working Width 14 5 2 Forward Speed Sensor 14 5 2 1 Select Sensor Option 14 5 2 2 Wheel sensor calibration Autocal 14 5 2 3 Wheel sensor calibration manually calculating the Fo...

Страница 5: ...y Alpha numeric values are entered via the right hand keypad You must press the key from 2 to 5 times to select the required letter Some keys have additional special characters not shown on the key le...

Страница 6: ...he contrast setting is adjusted so that the screen graphics can no longer be viewed i e completely light or dark don t panic you can navigate directly to the DISPLAY screen by pressing and holding the...

Страница 7: ...press 1 5 Select Control Software There are two lines displayed If the head unit does not have a secondary software module fitted both lines will be the same and switching between them has no effect I...

Страница 8: ...it is acceptable for the instrument to display a steady readout of 10 tonnes ha between those limits i e 3 In this case the rate lock on figure should be set to 3 0 Adjustable from 0 to 50 Default 2...

Страница 9: ...tem will resume DYNAMIC corrections This is to give the floor time to get to speed T Factor Delay This is the pause time after each new DYNAMIC correction has been made before the new correction start...

Страница 10: ...nu function immediately sends the data to the serial port The message Printing Data is displayed while data transfer is occurring If the bar on the screen stops filling up part way the instrument cann...

Страница 11: ...speed If necessary measure this speed using a hand held tachometer Note the speed displayed on the INFO screen The correct Cal factor Initial Factor x Displayed Speed Actual Speed Default 1 pulse per...

Страница 12: ...get rate then the response setting may be too high Default 100 Range 0 9999 3 4 3 Deadband The Deadband function sets the range over which the flow rate will vary about the target rate before the cont...

Страница 13: ...Rate This is the target application rate that is programmed on the MAIN screen Default 20 Range 0 9999 4 1 3 T Factor The T factor is the calibration factor that is altered while the spreader is disp...

Страница 14: ...the forward speed sensor This could be calculated based on the nominal tyre diameter or rolling distance and then entered manually ref section 1 1 3 however this does not take into account wheel slip...

Страница 15: ...for exactly 10 revolutions of the sensed wheel Measure this distance in inches or metres and divide by 20 to find the Speed Sensor Factor iii If 4 wheel magnets are installed the distance is 1 4 the...

Страница 16: ...e ALARMS SETUP button at the base of the screen 6 1 1 Low High RPM Alarm From the RPM SETUP screen you can also set a minimum and maximum RPM at which an alarm is triggered Set as necessary Default 0...

Страница 17: ...APOLLO FYM SPREADER CONTROLLER 17 Issue 1 12 12 13 Original Issue Issue 1 1 20 2 14 Ref CRQ5468...