APOLLO FYM - SPREADER CONTROLLER

8

2.

Technician Config

The operator is unlikely to need access in normal use. Access to this menu can be restricted by changing the

PIN number from within the menu.
Enter the factory default PIN number 1234 to access the menu.

2.1

Display Options

2.1.1 Speed Smoothing Factor

The  Forward  Speed  display  is  electronically  damped.  If  the  readouts  are  constantly  changing  by  small

increments, you can increase the damping time to give a steadier readout.

Adjustable from 0 to 19 seconds.

Default = 2 seconds

2.1.2 Rate Lock-On

"RATE LOCK-ON" sets the % by which the application rate fluctuates either side of a nominal application rate

before the instrument display changes.
For example, if the actual application rate fluctuates in normal operation from 9.7 to 10.3 tonnes/ha for a target

application rate of 10 tonnes/ha, you may decide that it is acceptable for the instrument to display a steady

readout of 10 tonnes/ha between those limits i.e. ±3%. In this case the rate lock-on figure should be set to 3.0.

Adjustable from 0 to 50%  Default = 2%

2.1.3 Rate Smoothing

The  Application  rate  display  is  electronically  damped.  If  the  readouts  are  constantly  changing  by  small

increments, you can increase the damping time to give a steadier readout.

Adjustable from 0 to 19 seconds.

Default = 2 seconds

2.1.4 Off Target Alarm

This  sets  the  threshold  at  which  the  instrument  will  alarm  "UNDER  APPLICATION"  or  "OVER  APPLICATION"

when Spreading in automatic control mode. It is set as a percentage either side of the current target rate.
Adjustable from 0 to 50%.

Default = 20%

2.1.5 Info Weight

Default = "

LOAD CELL

" - This means that the weight that is displayed on the INFO page as the job totals will

be  taken  from  the  load  cell  readings  (as  if  using  a  weigh  bridge)  instead  of  the  theoretical  weight  reading

based on the number of floor revolutions x calibration factor (

THEORY

)

2.

Technician Config.

1.

Display Options

UK572-12.PCX

Содержание Apollo FYM

Страница 1: ...1 Apollo FYM Spreader Controller Calibration RDS Part No Document Issue Software Issue S DC 500 10 746 1 1 20 2 14 PS605 001rev09...

Страница 2: ...sion Farming System the System are limited as set out in the specification of the System details of which are contained in the Help files and product literature and which must be read before using the...

Страница 3: ...e Smoothing 8 2 1 4 Off Target Alarm 8 2 1 5 Info Weight 8 2 2 Loadcell Correction 9 Correction Span 9 Min Stat Weight 9 Dynamic Time 9 Dynamic Weight 9 Start Delay 9 Steady Weight 9 H Land Delay 9 T...

Страница 4: ...dth 14 5 1 1 Set current Working Width 14 5 2 Forward Speed Sensor 14 5 2 1 Select Sensor Option 14 5 2 2 Wheel sensor calibration Autocal 14 5 2 3 Wheel sensor calibration manually calculating the Fo...

Страница 5: ...y Alpha numeric values are entered via the right hand keypad You must press the key from 2 to 5 times to select the required letter Some keys have additional special characters not shown on the key le...

Страница 6: ...he contrast setting is adjusted so that the screen graphics can no longer be viewed i e completely light or dark don t panic you can navigate directly to the DISPLAY screen by pressing and holding the...

Страница 7: ...press 1 5 Select Control Software There are two lines displayed If the head unit does not have a secondary software module fitted both lines will be the same and switching between them has no effect I...

Страница 8: ...it is acceptable for the instrument to display a steady readout of 10 tonnes ha between those limits i e 3 In this case the rate lock on figure should be set to 3 0 Adjustable from 0 to 50 Default 2...

Страница 9: ...tem will resume DYNAMIC corrections This is to give the floor time to get to speed T Factor Delay This is the pause time after each new DYNAMIC correction has been made before the new correction start...

Страница 10: ...nu function immediately sends the data to the serial port The message Printing Data is displayed while data transfer is occurring If the bar on the screen stops filling up part way the instrument cann...

Страница 11: ...speed If necessary measure this speed using a hand held tachometer Note the speed displayed on the INFO screen The correct Cal factor Initial Factor x Displayed Speed Actual Speed Default 1 pulse per...

Страница 12: ...get rate then the response setting may be too high Default 100 Range 0 9999 3 4 3 Deadband The Deadband function sets the range over which the flow rate will vary about the target rate before the cont...

Страница 13: ...Rate This is the target application rate that is programmed on the MAIN screen Default 20 Range 0 9999 4 1 3 T Factor The T factor is the calibration factor that is altered while the spreader is disp...

Страница 14: ...the forward speed sensor This could be calculated based on the nominal tyre diameter or rolling distance and then entered manually ref section 1 1 3 however this does not take into account wheel slip...

Страница 15: ...for exactly 10 revolutions of the sensed wheel Measure this distance in inches or metres and divide by 20 to find the Speed Sensor Factor iii If 4 wheel magnets are installed the distance is 1 4 the...

Страница 16: ...e ALARMS SETUP button at the base of the screen 6 1 1 Low High RPM Alarm From the RPM SETUP screen you can also set a minimum and maximum RPM at which an alarm is triggered Set as necessary Default 0...

Страница 17: ...APOLLO FYM SPREADER CONTROLLER 17 Issue 1 12 12 13 Original Issue Issue 1 1 20 2 14 Ref CRQ5468...

Отзывы: