SNV-12 Operations Manual
5-12
5.16
Default Transmit Site Selection
The Default TX Site is the site (or sites) that‟s normally keyed whenever console PTT is
activated “Normally keyed” is when neither automatic nor manual TX steering is choosing the
TX site. The two options are:
Home Site
Multicast
Home Site: Unless otherwise TX steered, when the Default TX Site selection is “Home Site”,
all console transmissions and Repeat Mode voted audio retransmissions are sent via the Home
Site only. The Home Site is the lowest-numbered SVM in the SNV-12 voting system that is
TX eligible. The Home Site transmitter is usually a general-coverage broadcast transmitter.
SVM numbering for a single chassis system starts with the SVM closest to the CPM-3 module
(the left-most SVM) and continues to the right, for SVMs numbering 1 through 12. For multi-
chassis systems, the Master SNV-12 contains SVM slots 1 through 12; the Expansion #1
chassis contains SVMs 13 through 24, and Expansion #3, SVMs 25 through 36. The Home
Site remains the lowest numbered TX-eligible site. SVM numbering does not change if some
SVM slots do not contain modules. For example, if there is no module in SVM slot #1 (the
left-most slot), the SVM in slot #2 is still numbered as SVM #2. All SVM slots are TX eligible
unless:
No SVM is present.
An SVM is configured as “RX-Only”.
An SVM is part of an RX Group, that group has a designated Primary Site (or
Sites), and the SVM is not a Primary Site.
If the current Home Site loses its TX eligibility, the Home Site status moves to the next-highest
numbered SVM that is TX eligible.
A site may be made temporarily unable to transmit if its PTT Inhibit input is activated on its
rear panel terminal block. The PTT Inhibit input does not affect TX eligibility. This means
that, if the TX Default site is the Home Site, and the PTT Inhibit input is activated on the Home
Site, the Home Site Status does not move to the next-highest numbered site. Therefore, no site
will be keyed unless TX Steering selects a TX eligible site other than the Home Site.
Note: A Line Fault indication does not cause a site to lose its TX eligible
status unless the failed site is a designated primary site and the “Group
Lockout With Primary
Site Failure” option is selected. This means that,
if the receiver at the Home Site fails, the SNV-12 will continue to key the
Home Site transmitter.
Multicast: Unless otherwise TX steered, when the Default TX Site selection is “Multicast”, all
console transmissions and Repeat Mode voted audio retransmissions are sent via
all
TX
eligible sites. The only exception is that when the SNV-12 is in the Simplex Mode,
retransmitted voted audio is not sent to the voted site.
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......