SNV-12 Operations Manual
3-49
SW1-6 Pilot Tone EOT Noise Cancellation
This switch is used to globally enable an end of transmission noise cancellation for all SVM-2
modules. Pilot tone operation can, with some radio equipment, cause an undesired noise burst
at the end of a field transmission. This feature has the effect of removing the last 200ms of
audio so that the noise burst is not heard. This is accomplished by delaying the audio output at
the SVM-2 by 200ms (approximately equal to the time it takes for the SVM-2 to detect pilot
tone, send that status to the CPM, and for the CPM to turn off the audio stream). This delay is
applied equally to all SVM-2 modules in the system. Note that SVM-1 modules do not support
this feature so enabling this for a system that has a mix of SVM-1 and SVM-2 modules will
cause an audio synchronization issue.
Table 3-33 Pilot Tone EOT Noise Cancellation
SW1-6
Repeat Mode Control
OFF
Disabled*
ON
Enabled
SW1-7 Manufacturing Test
This switch is used to enable Manufacturing Test Operation. This switch setting activates
features used only by us during manufacturing test. Leaving this switch ON will interfere with
normal SNV-12 operation.
NOTE: This switch must remain in the Off position for normal operation
of the SNV-12.
Table 3-34
Manufacturing Test Selection
SW1-7
Manufacturing Test
OFF
Disabled *
ON
Enabled
SW1-8 Default Transmit Site Selection (Multicast or Home Site)
This switch determines which site or sites are keyed when the site selection is not controlled by
automatic or manual TX steering. The choices are either the Home Site or Multicast. See
Section 4.15. The factory default destination is to the Home Site.
Multicast
refers to all
TX eligible
sites.
Home Site
refers to one site only, the lowest-numbered
TX eligible
site.
See Section 5.13, SNV-12 Transmit Features, for more in-depth information.
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......