SNV-12 Operations Manual
5-14
5.17.2
Holdover Timer With Momentary Manual TX Steering
The Holdover Timer is also active when TX steering selections are made via the MOM TX
SEL input on the SVM‟s rear panel terminal block or by the RS-232 MOM_TXSEL command.
Once a momentary transmit command is made, the Holdover Timer starts. Console
transmissions and repeat transmissions will be steered to the chosen site until the holdover
timer expires. The timer is refreshed every time the console PTT is activated and begins to run
again as soon as the PTT is deactivated. Voted audio from the field does not reset the timer.
Transmit selection remains with the chosen site until either the Holdover Timer expires or
another site is manually selected (both manual TX steering modes have precedence over
STARS).
5.17.3
Holdover Timer With Latched Manual TX Steering
The Holdover Timer does not come into play when non-momentary Manual TX Steering is
used. For these “latched” versions, the console transmissions and repeated transmissions will
be steered to the chosen site until the TX steering request is removed. When the rear panel
“TX Sel In” input is pulled low, the site will be TX steered until the input is allowed to return
high. If the RS-232 TXSEL command is issued, the specified site will remain TX steered until
a subsequent RS-232 command removes this selection.
5.17.4
Holdover Timer Examples
STARS, single site:
Start with no activity. The TX SEL site is the Default TX Site.
A site gets voted. TX SEL switches to the voted site.
When the vote ends, the TX SEL stays with this voted site for the duration of the
holdover timer, then returns to the Default TX Site.
STARS, multiple sites:
Start with no activity. TX SEL is the Default TX Site.
A site gets voted. TX SEL switches to the voted site.
A new site gets voted before all sites resquelch. Once the STARS weighting balance
switches to the newly voted site, it becomes the TX SEL site. If it doesn‟t stay voted
long enough (that is, more time in the previous 5 seconds than any other site) then it
won‟t become the TX SEL site.
When the vote sequence ends, the TX SEL stays with the site that last had this
designation during the vote for the duration of the holdover timer, then returns to the
Default TX Site.
Mom TX, single site:
Start with no activity. The TX SEL site is the Default TX Site.
1.
A site is selected by Mom TX as the TX SEL site. The holdover timer starts running as
soon as it‟s invoked. When it runs out, the TX SEL site designation returns to the
Default TX site.
2.
If the Mom TX is invoked again on the same site before the holdover timer expires, the
timer is reset and starts anew.
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......