SNV-12 Operations Manual
4-5
The system uses a similar scheme to share information between multiple chassis in a
Master/Expansion system. If a voter is configured as an "Expansion Chassis", it will read all
the Signal Quality information for each of its modules. It then calculates the "Best Signal
Quality Available" for its chassis. This information is passed on to the Master unit, which
compares this “Best SQ” with the SVMs in the Master Chassis. The Master then votes the best
SVM in the system; one of its modules or one of the Expansion chassis modules.
4.5.4
Fault LED
The red Fault LED will be illuminated whenever the associated module's built-in-test circuitry
detects a fault condition. The CPM-3 FAULT LED will flash during the unit power-up
sequence until all internal setup is complete and the unit is fully operational. This LED will
also light if the CPM-3 fails to establish communication with any of the Site Voter Modules
installed.
4.5.5
Master/Expansion 1/Expansion 2 LEDs
These LEDs flash during system power-up and when software is being downloaded from the
CPM-3 to other modules in the chassis. Otherwise, these LEDs are operational only when
multiple SNV-12s are daisy-chained together. The LEDs indicate where each unit fits in the
configuration. The MASTER unit is connected to the console and contains modules 1 through
12. The Expansion 1 chassis is connected to the MASTER chassis with SVMs 13 through 24.
The Expansion 2 chassis is used if the full complement of 36 modules is required.
4.5.6
Link LED
The Link led will flash during the CPM-3 power-up sequence. When the LINK LED is lit it
indicates that a network link to the CPM-3 is active.
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......