SNV-12 Operations Manual
3-8
Selecting the nearest larger capacity of a Panasonic battery:
18 AH Size: 7.3 x 4.9 x 6.5 inches LWH, Weight: 17 lb.
22 AH Size: 4.9 x 6.5 x 6.9 inches LWH, Weight: 19 lb.
35 AH Size: 7.8 x 6.5 x 6.9 inches LWH, Weight: 28 lb.
In addition, for batteries sized to provide more than one hour of backup, chargers will have to
be provided, as the charger built into the SNV-12 can only supply 1 A, so it would take too
long to recharge the batteries necessary for an 8 HR backup time.
3.6.2.3
Charge Switch
The CHARGE Switch, SW3, should be set to CHARGE only if a back-up battery is being used.
CAUTION
:
Always disconnect both the AC and DC input power cabling
from the SNV-12 prior to servicing the unit.
3.7
Fuse Information
This section identifies the three fuses used in the SNV-12 chassis. Be sure to remove all AC &
DC input cabling prior to removing or servicing the PSM-1. F1 fuses the unfiltered low level
DC bus voltage from the PSM-1 that powers the +5V DC switching supplies on each of the
other chassis modules. It can only be replaced if the PSM-1 is removed from the chassis. F1
prevents damage to the PSM-1 if a short circuit or other unusual load is applied to this bus. If
AC is applied and the AC LED is lit, the +12V and –12V LEDs should light when the PSM-1
front panel pushbutton power switch is pushed in. If they do not, this is an indication that Fuse
F1 is blown or possibly another type of fault in the PSM-1. Similarly, if the unit is running off
of a 12 VDC supply source and the DC LED is lit, the +12V and –12V LEDs should light when
the main power pushbutton is pressed.
If AC is applied but the AC LED on the PSM-1 is not lit, then the AC Input Fuse, F2, is
probably blown (or there is another fault in the PSM-1). If DC is applied but the DC LED on
the PSM-1 is not lit, then the DC Input Fuse, F3, is probably blown (or less likely, there is
another fault in the PSM-1). Both of these fuses may be accessed at the rear of the unit.
Table 1
SNV-12 Fuses
F1
10AF 250V, 3AG
DC Bus
Low voltage DC to each SNV-12 module
F2
3AT 250V, 5x20mm
AC Input
AC Line Fuse (115 VAC nominal)
1.6AT 250V, 5x20mm AC Input
AC Line Fuse (230 VAC nominal)
F3
20AF 32V, 3AG
DC Input
DC Power Input Fuse (12 VDC nominal)
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......